EDID Management
This Matrix has 21 factory defined EDID settings, 2 user-defined EDID modes and 16 copy EDID
modes. You can select defined EDID mode or copy EDID mode to input port through front panel
buttons, RS-232 control or Web GUI.
On-panel button operation:
On the initial OLED display screen, press
“MENU” button to enter
the EDID setting interface, press “UP/DOWN” button to select the required EDID, and press
the
“ENTER” button. A prompt “copy to input :” will appear. Then press “UP/DOWN” button to
select the input port you
need to set, and press “ENTER” button again to confirm this operation
.
RS-232 control operation:
Connect the Matrix to PC with a serial cable, then open a Serial
Command tool on PC to send ASCII command “s edid in x from z!” to set EDID. For details,
plea
se refer to “EDID Setting” in the ASCII command list of “9. RS-232 Control Command”.
Web GUI Operation:
Please check the EDID management in the “Input page” of “8. Web
GUI User Guide”.