Auto setting
When the pulse speed switch is set to “Auto”, the pulse speed varies according to the battery
charge level.
Battery charge level Pulse speed
Optimal
Fast – approximately 1.5 seconds between pulses
Medium
Slow – approximately 2.5 seconds between pulses
Low
Very slow – approximately 3.5 seconds between pulses
Battery test setting
When the power output switch is set to “Full power with battery test”, the indicator lights show
the charge level of the battery and other battery information. The battery test is only relevant
when a lead-acid battery is used. The table below explains what the indicator lights represent
and any action required for each installation.
Lights
Battery-only energisers
Battery energiser with solar panel
Green light Optimal battery charge level:
Optimal battery charge level (Readings for
on
• No action required.
a solar installation are only accurate in the
early morning or late evening when the
solar panel has been out of the sunlight for
several hours.)
Yellow light Medium battery charge level
Low to medium battery charge level:
on
• Monitor battery charge level.
• Recharge the battery immediately.
• Recharge the battery to avoid
• Check the solar panel wiring is con-
long term battery damage.
nected properly and is intact.
• Check that the solar panel is installed
correctly and is clean.
If the problem recurs, the panel may be
inadequate or faulty.
• Take the entire system to an authorised
service agent for assessment.
Red light on Low battery charge level:
Low battery charge level:
• Recharge the battery
• See low to medium battery charge level
immediately
above
Green light Not applicable
Battery connections may be faulty
flashing
• Check that the battery clips are connected
- 39 -