Installing the gateway
23
SmartNode 4970A User Manual
3
• SmartNode installation
Connect the cables in the following order:
1.
Connect the T1/E1 cables to the PRI T1/E1 ports (see
2.
Connect the 10/100/1000Base-T Ethernet (see section
“Connecting the 10/100/1000Base-T Ethernet
3.
Connect the power mains cable (see section
Connecting the PRI
The SmartNode comes with one or four PRI ports. These ports are usually connected to a PBX or switch (local
exchange (LE) ). Each PRI T1/E1 port is a RJ-48C receptacle. In most cases, a straight-through RJ-45 can be used
to connect the PRI. Each port can be configured as NT (clock master) or TE (clock slave).
For details on the PRI port pin-out and ISDN cables, refer to Appendix C, “Cabling” on page 43 and Appen-
dix D, “port pin-outs” on page 47.
Connecting the 10/100/1000Base-T Ethernet cable
The SmartNode 4970A has automatic MDX (auto-crossover) detection and configuration on the Ethernet
port. The port can be connected to a host or hub/switch with a straight-through or cross-over wired cable.
Connect the LAN network to
ETH 0/0
.
Note
The SmartNode Ethernet port operates in Full Duplex mode only. Do not
connect to Half Duplex ports. For best results, use auto-negotiation. Auto
negotiation is mandatory when using 1000BaseT (Gigabit) Ethernet.
For details on the Ethernet port pinout and cables, refer to Appendix C, “Cabling” on page 40 and Appendix
D, “Port pin-outs” on page 46.
The interconnecting cables shall be acceptable for external use
and shall be rated for the proper application with respect to volt-
age, current, anticipated temperature, flammability, and
mechanical serviceability.
CAUTION
Содержание SmartNode 4970A Series
Страница 18: ...18 Chapter 2 Applications overview Chapter contents Introduction 19 Application Convert Legacy PBX to VoIP 19...
Страница 40: ...40 Appendix C Cabling Chapter contents Introduction 41 Console 41 Ethernet 42 E1 PRI 43 T1 PRI 44...
Страница 46: ...46 Appendix D Port pin outs Chapter contents Introduction 47 Console port 47 Ethernet 47 PRI port 48...
Страница 49: ...49 Appendix E SmartNode 4970A factory configuration Chapter contents Introduction 50...