101
CLEARANCE TO NON-COMBUSTIBLE
CONSTRUCTION
A minimum of 3”/7.62 cm clearance from the
back of the grill to non-combustible
construction is required for the lid to open fully.
DO NOT INSTALL THIS UNIT INTO
COMBUSTIBLE ENCLOSURES!
MINIMUM CLEARANCE:
24 in/61 cm Clearance from all sides to
combustible material.
Always place the gas cylinder within reach
and in a well ventilated area, do not subject
gas cylinder to excessive heat.
LOCATION
When determining a suitable location take into
account concerns such as exposure to wind,
proximity to traffic paths and keeping any gas supply
lines as short as possible. Locate the grill only in a
well-ventilated area. Always keep the hose in sight.
Never locate the grill in a building, garage,
breezeway, shed or other such enclosed areas.
During heavy use, the grill will produce a lot of
smoke.
For protection against bad weather: when the
BBQ is not in use, keep the unit covered with the
cover delivered with the BBQ.
BUILT-IN GRILL SPECIFICATIONS
DESCRIPTION 740-0059
420-0063
740-0549 740-0354A
Cut out width
70,4cm / 7,72inch
70,4cm / 27,72inch
101,6cm / 40inch
106,68cm / 42inch
Cut out depth
46,6cm / 18,35inch
46,6cm / 18,35inch
48,26cm / 19inch
53,34cm / 21inch
Cut out height
27,4cm / 10,8inch
27,4cm / 10,8inch
27,62cm / 10,8inch
36,2cm / 14,25inch
Non-combustible Island
surface
X X X
X
PLACEMENT OF THE GRILL
5 in
.(12
.7
0cm
)
17 in.
(43.
18
cm)
A minimum of
7 1/4in.(18.5cm)
clearance
from the back of the grill is required
to non-combustible material.
WARNING
Do not install this unit into combustible enclosures.
There should be a minimum clearance of at least
24 in.(60.96cm) from all sides to combustible
materials.
27.7
2 in
.(70
.4cm
)
18
.35
in
.(4
6.6
cm
)
1
0
.8
i
n
.(
2
7
.4
c
m
)
BUILD-IN GRILL SPECIFICATIONS
ISLAND CONSTRUCTION 740-0059 / 420-0063