Installing the IpChannel Bank
31
SmartNode 4900 Series Getting Started Guide
3 • Hardware installation
Connecting a 10/100Base-T Ethernet port to an Ethernet-capable workstation. The 10/100Base-T Ether-
net ports can connect to a single Ethernet-capable workstation or PC by means of any Ethernet cable.
Connecting the EIA-561 RS-232 configuration port (DCE configured)
Install the supplied RJ-45-to-RJ-45 cable with the DB9-RJ45 adapter between the SN4900 IpChannel Bank
RS-232 console port (
figure 10
) and an open serial port on your computer. If you need to assemble your own
cable, refer to the pinout diagram in
figure 10
.
Figure 10. DB-9-to-RJ-45 cable diagram
Connecting the serial port
Serial devices (V.35 or X.21) are connected to the SmartNode’s serial ports (see
table 8
) via a cable terminated
at the SmartNode 4900. The V.35 connector is a DB-25 female and the X.21 uses a DB-15 female. The sync
serial ports are configured as DTE.
Table 8. Serial port pin-outs
V.35 Interface (DB-25)
X.21 interface (DB-15)
Pin
Description
Pin
Description
1
Frame Ground
1
Signal Ground
2
TD-a (to DCE)
2
Transmit (to DCE)
3
RD-a (from DCE)
3
Control (to DCE)
4
RTS (to DCE)
4
Receive (from DCE)
5
CTS (from DCE)
5
Indication (from DCE)
6
DSR (from DCE)
6
Signal Element Timing (from DCE)
7
Signal Ground
8
DTE Common Return
8
CD (from DCE)
9
Transmit (to DCE)
9
RC-b (from DCE)
10
Control (to DCE)
11
XTC-b (to DCE)
11
Receive (from DCE)
12
TC-b (from DCE)
12
Indication (from DCE)
14
TD-b (to DCE)
13
Signal Element Timing (from DCE)
15
TC-a (from DCE)
16
RD-b (from DCE)
17
RC-a (from DCE)
20
DTR (to DCE)
6 DSR
1 CD
4 DTR
5 SG
2 RD (driven)
3 TD (received)
8 CTS
7 RTS
1
2
3
4
5
6
7
8
DSR & DTR are internally
wired together
RJ-45 Jack
Signal Name
DB-9