manualshive.com logo in svg
background image

USER
MANUAL

MODEL 2400

56/64 Kbps, 4-Wire DDS 
and Clear Channel CSU/DSU

SALES OFFICE
(301) 975-1000
TECHNICAL SUPPORT
(301) 975-1007
http://www.patton.com

Part# 07M2400-B
Doc# 099041UB
Revised 7/16/97

C E R T I F I E D

An ISO-9001

Certified Company

Содержание Patton SmartNode 2400 Series

Страница 1: ...00 56 64 Kbps 4 Wire DDS and Clear Channel CSU DSU SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2400 B Doc 099041UB Revised 7 16 97 C E R T I F I E D An ISO 900...

Страница 2: ...radio frequency equipment the user is strongly advised to only use data cables with an external outer shield bonded to a metal or metalized connector 1 2 FCC INFORMATION The Model 2400 Series has been...

Страница 3: ...network receive recovered clock Connecting directly to the RS 232 V 24 Model 2400 A or V 35 Model 2400 C port the ultra compact Model 2400 attaches without using additional cables The Model 2400 s bu...

Страница 4: ...and loop control Figures 3 Model 2400 A and 4 Model 2400 C show the switch and jumper locations with respect to the other components on bottom side the PC board Figure 5 below shows a close up of DIP...

Страница 5: ...s On 64 Kbps NOTE Power must be cycled off and then on to reset the Data Rate Switch S1 6 Front Panel Switch Enable Disable Switch S1 6 determines whether the front panel switches may be used to perfo...

Страница 6: ...s not used for interface power JP1 Position 1 4 Normal default Position 4 5 Pin 9 Used for Interface Power In this setting the 2400 A is powered from the DTE interface Power should be applied to pin 9...

Страница 7: ...erface the DTE terminal interface and the AC power supply 4 1 LINE NETWORK CONNECTION The RJ 48S port on a Model 2400 CSU DSU is prewired for a standard TELCO wiring environment as in Figure 4 below C...

Страница 8: ...his connects with one of several available country specific power cords see the ordering information in Appendix C You may purchase these power cords from Patton Electronics or from a local vendor of...

Страница 9: ...54 and V 52 test modes 5 1 FRONT PANEL LED STATUS MONITORS The Model 2400 features five front panel status LEDs that indicate the condition of the unit and communication link Figure 12 below shows the...

Страница 10: ...oped back To perform an RDL test follow these steps 1 Activate RDL This may be done in two ways first by moving the front panel toggle switch UP to RDL second by raising the appropriate pin on the ter...

Страница 11: ...e Modems SRMs are tested to the distances published in our Catalogs and Specification Sheets on twisted pair cable with the following characteristics Wire Gauge Capacitance Resistance 19 AWG 83nF mi o...

Страница 12: ...itzerland Power Cord 07M2400 A User Manual APPENDIX D MODEL 2400 INTERFACE PIN ASSIGNMENT DDS CLEAR CHANNEL INTERFACE The DDS Clear Channel Interface is an RJ 48S modular jack Pin Signal 1 TX Line Tra...

Страница 13: ...5 CTS Clear to Send 6 DSR Data Set Ready 7 SGND Signal Ground 8 CD Carrier Detect 9 User Selectable Supplemental Power Input or Not Used 15 TC Transmit Clock 17 RC Receive Clock 18 LL Local Loop 21 U...

Отзывы: