3. Connecting the OnSite to the network
31
OnSite Model 2884 User Manual
4 • Initial configuration
login:
admin
password:
Trinity#
Changing the IP address
You can set your IP address and network mask for the interface
ETH 0 (LAN)
. Within this example a network
192.168.1.1/24 address is assumed. The IP address in this example is set to
192.168.1.1
(you should set this
the IP address given to you by your network provider).
Trinity# configure
Trinity[config]# interface ethernet eth0
Trinity[eth-eth0]# no ip address 192.168.200.10
Trinity[eth-eth0]# ip address 192.168.1.1 netmask 255.255.255.0
Copy this modified configuration to your new start-up configuration. This will store your changes in non-vol-
atile memory. Upon the next start-up the system will initialize itself using the modified configuration.
Trinity#
copy running-config startup-config
Trinity#
The OnSite can now be connected to your network.
3. Connecting the OnSite to the network
In general, the OnSite will connect to the network via the
LAN (ETH 0)
port. This enables the OnSite to offer
routing services to the PC hosts on
LAN (ETH 1)
port. The OnSite 2884 Series is equipped with Auto-MDX
Ethernet ports, so you can use straight-through or crossover cables for host or hub/switch connections.
You can check the connection with the ping command from the OnSite to another host on the network.
Trinity#ping <IP Address of the host>
Note
If the WAN address is
not
set to DHCP, to ping a device outside your local
LAN you must first configure the default gateway.
Note
For more detailed configuration instructions, see the
TrinityAE Administra-
tor’s Reference Guide
available online at
www.patton.com/manuals/Trinity-
arg.pdf
.
The interconnecting cables shall be acceptable for external use
and shall be rated for the proper application with respect to volt-
age, current, anticipated temperature, flammability, and
mechanical serviceability.