3.0 Connect to the local IP network
Connect the OnSite’s (green)
Ethernet
port to the same Ethernet segment as your PC (see
figure 3
).
Note
The Model 2620 does not have an MDI-X switch, so you must use a cable wired straight-through to con-
nect the Model 2620’s Ethernet port to the IP network.
If you have a Model 2603, press the MDI-X switch until the
Ethernet Link
LED turns on.
Figure 3.
Connecting the OnSite to the local IP network (Model 2603/K shown)
You can check the network connection with the ping command. For example, you would ping
10.10.10.5
from
your PC.
4.0 Log onto the web management interface
You will now access the web management Graphical User Interface (GUI) to configure the OnSite using a stan-
dard web browser (such as Internet Explorer or Netscape browser).
1.
At your PC, open a web browser and enter the IP address you assigned to the OnSite’s Ethernet LAN port
in step 2 of section
2.2 “Modifying the IP address”
on page 4.
2.
Log in to the web management home page using the username
superuser
and the password
superuser
.
Crossover
10/100
Ethernet
WA
N
Power
MDI-X
RX
TX
Connect to
Ethernet port
Ethernet port
MDI-X switch
PC