manualshive.com logo in svg
background image

4.2  CONNECTION TO THE 4-WIRE INTERFACE

The Model 1012AR offers RJ-11 and RJ-45 options for connection

of the 4-wire data line.  The signals/pins used are shown below:

RJ-11

SIGNAL

RJ-45

SIGNAL

1 ------------GND

1 -----------N/C

2 ------------RCV-

2 -----------GND

3 ------------XMT+

3 -----------RCV-

4 ------------XMT-

4 -----------XMT+

5 ------------RCV+

5 -----------XMT-

6 ------------GND

6 -----------RCV+
7 -----------GND
8 -----------N/C

Connection to ground is optional

4.2.1  POINT-TO-POINT CONNECTION

When installing two Model 1012AR units in a point-to-point appli-

cation, the cable between them should be a 

crossover cable, as shown

in the following chart.  The color/pin number correlations below corre-
spond to AT&T’s wiring standard for RJ-11 connectors.

SIGNAL

PIN#

COLOR

COLOR

PIN#

SIGNAL

GND

1

Blue

--------------White

6

GND

RCV-

2

Yellow ------------Red

4

XMT-

XMT+

3

Green ------------Black

5

RCV+

XMT-

4

Red ---------------Yellow

2

RCV-

RCV+

5

Black -------------Green

3

XMT+

GND

6

White -------------Blue

1

GND

Connection to ground is optional

Standard color codes—yours may be different

4.3  MULTIPOINT CONNECTION

The Model 1012AR supports multi-point applications using either

a star or a daisy chain topology.  together in a master/slave arrange-
ment.  Maximum distance between the units will vary based upon the
number of drops, data rate, wire gauge, etc.  Call Technical Support for
specific distance estimates.  In both topologies, the master unit should
be set to “transmitter constantly on” (strap removed), and the slaves
should be set to “transmitter controlled by RTS” (strap in place).

4.3.1  STAR TOPOLOGY

Figure 4 (below) shows how to wire the two-pair cables properly

for a Model 1012AR star topology.  Note that the ground connection is
not needed

4.3.2  DAISY CHAIN TOPOLOGY

Figure 5 (below) shows how to wire the two-pair cables properly

for a Model 1012AR daisy-chain topology.  Note that the ground con-
nection is not needed.

5

6

1 - Blue
2 - Orange
3 - Black
4 - Red
5 - Green
6 - Yellow
7 - Brown
8 - Slate

1 - Blue
2 - Yellow
3 - Green
4 - Red
5 - Black
6 - White

HOST

FIRST SLAVE

SECOND SLAVE

XMT+

RCV+

RCV+

XMT-

RCV-

RCV-

RCV+

XMT+

XMT+

RCV-

XMT-

XMT-

Figure 4. Star wiring for Model 1012AR host and slaves

HOST

FIRST SLAVE

OTHER SLAVE(S)

XMT+

RCV+

RCV+

XMT-

RCV-

RCV-

RCV+

XMT+

XMT+

RCV-

XMT-

XMT-

Figure 5. Daisy chain wiring for Model 1012AR host and slaves

Отзывы: