manualshive.com logo in svg
background image

TABLE OF CONTENTS

1.0 Warranty Information.................................................................2

1.1  Radio and TV Interference
1.2  Service 

2.0 General Information...................................................................3

2.1  Features

2.2  Description

3.0 Installation ..................................................................................4

3.1  Connecting the Main Channel
3.2  Connecting the Sub-Channels
3.3  Connecting Two Model 3022s Back-to-Back
3.4  LED Status Indicator
3.5  Power Requirements
3.6  Flow Control Requirements

4.0 Operating Modes........................................................................9

4.1  Local Offline Command Mode

4.2  Online Data Mode

4.3  PassThru Mode

4.4  Local Online Command Mode

4.5  Remote Online Command Mode

5.0 Command Entry .......................................................................11

5.1  Rules for AT Command Entry
5.2  Result Codes
5.3  Complete AT Command Set

6.0 Tutorial ......................................................................................19

7.0 Troubleshooting .......................................................................23

Appendix A - Specifications

Appendix B - Sub-Channel Cables

1

1.0  WARRANTY INFORMATION 

Patton Electronics warrants all Model 3022 components to be

free from defects, and will—at our option—repair or replace the product
should it fail within one year from the first date of shipment.

This warranty is limited to defects in workmanship or materials, and

does not cover customer damage, abuse, or unauthorized modification.
If this product fails or does not perform as warranted, your sole
recourse shall be repair or replacement as described above.  Under no
condition shall Patton Electronics be liable for any damages incurred
by the use of this product.  These damages include, but are not limited
to, the following:  lost profits, lost savings, and incidental or
consequential damages arising from the use of or inability to use this
product.  Patton Electronics specifically disclaims all other warranties,
expressed or implied, and the installation or use of this product shall be
deemed an acceptance of these terms by the user. 

1.1  RADIO AND TV INTERFERENCE

The Model 3022 generates and uses radio frequency energy, and if

not installed and used properly—that is, in strict accordance with the
manufacturer's instructions—may cause interference to radio and
television reception.  The Model 3022 has been tested and found to
comply with the limits for a Class A computing device in accordance
with the specifications in Subpart J of Part 15 of FCC rules, which are
designed to provide reasonable protection from such interference in a
commercial installation.  However, there is no guarantee that
interference will not occur in a particular installation.  If the Model 3022
does cause interference to radio or television reception, which can be
determined by disconnecting the RS-232 interface, the user is
encouraged to try to correct the interference by one or more of the
following measures:  moving the computing equipment away from the
receiver, re-orienting the receiving antenna, and/or plugging the
receiving equipment into a different AC outlet (such that the computing
equipment and receiver are on different branches).

1.2  SERVICE

All warranty and non-warranty repairs must be returned freight

prepaid and insured to Patton Electronics.  All returns must have a
Return Materials Authorization number on the outside of the shipping
container.  This number may be obtained from Patton Electronics
Technical Service at (301) 975-1007.  

Packages received without an

RMA number will not be accepted.

Patton Electronics' technical staff is also available to answer any

questions that might arise concerning the installation or use of your
Model 3022.  Technical Service hours:  8AM to 5PM EST, Monday
through Friday.

2

Содержание MicroStat II 3022

Страница 1: ...USER MANUAL MODEL 3022 MicroStat II Miniature Statistical Multiplexer SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M3022 B Doc 068021UB Revised 12 19 95...

Страница 2: ...nstallation or use of this product shall be deemed an acceptance of these terms by the user 1 1 RADIO AND TV INTERFERENCE The Model 3022 generates and uses radio frequency energy and if not installed...

Страница 3: ...X ON X OFF flow control Connecting directly to the modem s DB 25 port the Model 3022 derives power from the RS 232 interface and requires no AC power or batteries for operation Async input devices con...

Страница 4: ...20 DTR 3 7 SG 4 3 RX Data 5 2 TX Data 6 5 CTS 7 4 RTS 8 continued PC AT to Model 3022 Pin Outs Serial DB 9 Model 3022 RJ 45 Pin No Pin No 6 DSR 1 1 CD 2 4 DTR 3 5 SG 4 2 RCV Data 5 3 TX Data 6 8 CTS 7...

Страница 5: ...devices connected to sub channels 1 and 2 must support local flow control flow control between the device and the sub channel port In all cases the flow control setting of each Model 3022 port must m...

Страница 6: ...operate the Model 3022 it is important to know how the unit handles command entry This section provides rules for command entry describes result codes and gives a complete description of each valid A...

Страница 7: ...__________________________________________________ AT Command line prefix The attention command precedes all other commands listed below Directs the local Model 3022 to execute the following commands...

Страница 8: ...nute n 4 1 minute n 5 75 seconds n x x 4 minute Note if K0 is selected the local Model 3022 will stay in Local Offline Command Mode indefinitely until either CD of the main channel becomes active if t...

Страница 9: ...oftware reset with all Model 3022 modes and channel configurations set to previously stored values The Model 3022 will then enter offline command mode Note The user must wait approximately 5 seconds a...

Страница 10: ...22 Using these instructions plus the AT command descriptions in Section 5 0 you should be able to operate the Model 3022 in almost any application If you have additional questions do not hesitate to c...

Страница 11: ...and repeat the above process for sub channel 2 6 If all three sets of parameters match those of your system move to step 4 continued 19 20 Step 1 Verifying Local Setup Parameters The first step in us...

Страница 12: ...well Any configuration changes you have entered will be stored in the Model 3022 s non volatile memory if they have been saved with the AT W or AT W command 21 22 7 0 TROUBLESHOOTING SYMPTOM POSSIBLE...

Страница 13: ...ds power Plug it into an RS 232 port or obtain Model 3P MF power supply adapter SYMPTOM POSSIBLE PROBLEM SOLUTION 8 Modem connection has been established but 3022 will not pass data Model 3022 is stil...

Страница 14: ...te 3022 times out or issue AT O to remote 3022 Issue AT Y0 to Model 3022 Consult modem manual SYMPTOM POSSIBLE PROBLEM SOLUTION APPENDIX A SPECIFICATIONS Sub Channels Serial Devices Interface RJ 45 V...

Страница 15: ...om the model number suffix combinations shown on the previous page Do not combine these part numbers with the model number of the standalone unit when ordering These are separate items Patton Part Num...

Отзывы: