EHA3201 Quick Start Guide

Note

It does not matter whether the positive (+) or negative (-) side of the DC power supply is grounded. 
However, the polarity on the power source must be matched up properly to the EHA3201 power input 
(i.e. negative power source terminal to negative power input; positive power source terminal to positive 
power input). 

2.0  Configuring the EHA3201

The EnviroNET G.SHDSL Router comes pre-configured to communicate with other devices on the network. To 
futher configure the EHA3201, you may log into the web management system. 

2.1  Connect to a PC

   1.

Connect the EHA3201’s 

Data

 port to your PC (see 

figure 5

). 

   2.

The PC used for configuring the EHA3201 should be set for DHCP client. 

   3.

Connect the EHA3201 to a power source to turn on the unit. 

   4.

The EHA3201 

Data 

port uses the DHCP client to automatically assign an IP address and netmask. The 

EHA3201 will send the IP address to the PC.

   5.

Enter the EHA3201’s IP address in the address bar of the web browser. 

   6.

Log in and perform any desired configuration changes through the EHA3201’s web browser interface. 

Figure 5. 

Connecting the EHA3201 to the local IP network

For information on changing the IP address, refer to Chapter 3 “Quick Start Installation” in the 

Model 3201 & 

3241 User Manual

Connect to

Ethernet port

(DATA)

Ethernet port

PC

Enviro

NET

ª

PO

WE

R

DA

TA

LIN

E

Содержание ENVIRONET EHA3201

Страница 1: ...intended for use in a light industrial environment It is not intended nor approved for use in an industrial or residential environment Part Number 07MEHA3201 QS Rev C Revised February 16 2012 Sales O...

Страница 2: ...evices ensure that the interconnecting cables are rated for proper voltage current anticipated temperature flammabil ity and mechanical serviceability WAN LAN PSTN ports connections may have hazardous...

Страница 3: ...static Discharge ESD can damage equipment and impair electrical circuitry It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures Do...

Страница 4: ...ed dry metal wire between 19 0 9mm and 26 AWG 0 4mm Leased circuits that run through signal equalization equipment are not acceptable The G SHDSL Router is equipped with an RJ 45 interface jack Line w...

Страница 5: ...G SHDSL Router does not have a power switch so it powers up as soon as it is plugged in There are no user serviceable parts in the EnviroNET G SHDSL Router Fuse replacement should only be performed b...

Страница 6: ...C 1 Connect the EHA3201 s Data port to your PC see figure 5 2 The PC used for configuring the EHA3201 should be set for DHCP client 3 Connect the EHA3201 to a power source to turn on the unit 4 The EH...

Страница 7: ...Manual For a routed application connecting the CPE to a DSLAM see pages 46 77 in the Model 3201 3241 User Manual 3 0 Additional Information For detailed information about configuring and operating gu...

Страница 8: ...AC 110 220VAC 2 25W B 2 Temperature Range 40 185 F 40 85 C B 3 Humidity Up to 90 non condensing B 4 Dimensions 8 H x 9 25 W x 3 25 D B 5 Weight 6 4lb 2 9kg Note For Model 3201 unit specifications refe...

Страница 9: ...otify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone com pany will notify the customer as soon as possible Also you will be...

Страница 10: ...lity designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect...

Страница 11: ...elecommunication Terminal Equip ment and the mutual recognition of their conformity The signed Declaration of Conformity can be downloaded from www patton com certifications C 6 Authorized European Re...

Страница 12: ...iability for errors that may appear in this document Trademarks statement The term EnviroNET is a trademark of Patton Electronics Company All other trademarks presented in this docu ment are the prope...

Страница 13: ...tart Guide 13 D 0 Buccaneer 400 Series Environmentally Sealed Connectors The following instructions are provided by Bulgin UK for assembling the 400 Series Buccaneer IP68 Sealed Electrical Cable Conne...

Страница 14: ...14 EHA3201 Quick Start Guide...

Страница 15: ...EHA3201 Quick Start Guide 15...

Страница 16: ...16 EHA3201 Quick Start Guide...

Отзывы: