3. Connect the braided ground strap directly to a frame ground
connection on the protected device. If you are unsure where to
locate a frame ground connection on your equipment, be sure to
consult the equipment user manual or contact the manufacturer —
the ground connection is critical for proper operation of the Model
533.
APPENDIX A
SPECIFICATIONS
Interface: ArcNet (IEEE 802.3) BNC coaxial
Size: 2.0" long x 1.0" diameter
Circuit: Bipolar, solid state, bi-directional protection on BNC
connectors
Response Time: Less than 5 nanoseconds
Input Capacitance: 18 pF
Clamp Voltage: 35 volts at 100A (8/20 µ Waveform)
Surge Current: 400A (8/20 µ Waveform)
Energy Handling: 1500 Watts per wire
Transfer Loss: -.05dB at 100 MHz
Group Delay: None, 1 MHz to 100 MHz
Series Resistance: None
Grounding: External connection provides separate unit-ground to
chassis-ground contact
3
4
Coaxial input
from network
Coaxial input from
network
Connection to
frame ground
M o d e l 5 3 3 ArcNet
Surge Protector