3.  Connect the braided ground strap directly to a frame ground

connection on the protected device.  If you are unsure where to
locate a frame ground connection on your equipment, be sure to
consult the equipment user manual or contact the manufacturer —
the ground connection is critical for proper operation of the Model
533.

APPENDIX A

SPECIFICATIONS

Interface:  ArcNet (IEEE 802.3) BNC coaxial

Size:  2.0" long x 1.0" diameter

Circuit:  Bipolar, solid state, bi-directional protection on BNC

connectors

Response Time:  Less than 5 nanoseconds

Input Capacitance: 18 pF

Clamp Voltage:  35 volts at 100A (8/20 µ Waveform)

Surge Current:  400A (8/20 µ Waveform)

Energy Handling:  1500 Watts per wire

Transfer Loss:  -.05dB at 100 MHz

Group Delay: None, 1 MHz to 100 MHz

Series Resistance: None

Grounding:  External connection provides separate unit-ground to

chassis-ground contact

3

4

Coaxial input
from network

Coaxial input from

network

Connection to

frame ground

M o d e l   5 3 3    ArcNet

Surge Protector