3.0 INSTALLATION
Patton's Model 532S units are easy to install and should give you
years of trouble-free service. Here are a few simple instructions to help
you get things hooked up right.
1. Unplug (disconnect) the existing connection between the network
cable and the equipment’s I/O port.
2. Install the Model 532S between the incoming network cable and
the protected equipment using the 6” (15.24cm) modular patch
cable (supplied). Place the surge protector as close as possible to
the device being protected.
3. Connect the braided ground strap directly to a chassis ground
connection on the protected device. If you are unsure where to
locate a chassis ground connection on your equipment, consult the
equipment's user manual or contact the manufacturer—the ground
connection is critical for proper operation of the Model 532S.
3
Output to Protected
Equipment
Input from
Network
Connection to
Frame Ground
APPENDIX A
532S SPECIFICATIONS
Protocol/Application: IEEE 802.5 Token Ring, shielded or
unshielded twisted pair
Circuit:
Bipolar, Solid State, 4-wire bi-directional
protection on RJ-45 connectors
Maximum Signal Rate: 10 Mbps
RJ-45 Pins Protected: 3, 4, 5 and 6
Response Time:
Clamps to 7.5V in 0.5µ Sec
Capacitance:
18 pF
Surge Current:
400A (8 x 20 S.C. Waveform)
Energy Handling:
1.5 KW for 1 msec
Grounding:
External connection provides separate unit-
ground to chassis-ground contact
Size:
3.05” x 1.68” x 0.81” (7.74cm x 4.26cm x
2.06cm)
Copyright ©
Patton Electronics Company
All Rights Reserved
4
Figure 1. How to Connect the Patton Model 532S