background image

The table below shows the factory default jumper settings for the

Model 1000RCM703120 DB25/RJ-45 rear card. Following the table is
a description of each jumper’s function and possible settings. When
configuring the jumpers, take care not to lose the individual straps.

LK1: (Receive Pair) Pin 2-to-Ground Connection

This setting determines whether or not pin 2 of the receive pair is

sent to earth ground. This connection should not be made in most
cases.

LK1

Setting

Strap On

Pin 2-to-GND Connection Made

Strap Off

Pin 2-to-GND Connection Broken

LK2: Receive Shield (Pin 3)-to-Ground Connection

This setting determines whether or not the RX shield (pin 3) is

connected to earth ground. This connection may help EMC perform-
ance in some cases.

LK2

Setting

Strap On

Pin 3-to-GND Connection Made

Strap Off

Pin 3-to-GND Connection Broken

LK3: (Transmit Pair) Pin 4-to-Ground Connection

This setting determines whether or not pin 4 of the transmit pair is

sent to earth ground. This connection should not be made in most
cases.

LK3

Setting

Strap On

Pin 4-to-GND Connection Made

Strap Off

Pin 4-to-GND Connection Broken

LK4: Clock Synchronization (EIA-530/V.35 vs. X.21)

This setting determines whether clocks are common or separate.

Separate (non-synchronized) clocks are used for the EIA-530/V.35 ter-
minal interface. Common (synchronized) clocks are used for the X.21
terminal interface. If clocks are synchronized, a DB-25 to DB-15
adapter cable should be used between the Model 2703RC and the
X.21 terminal device (see Appendix B and Appendix C for details).

LK4

Setting

Strap On

Clocks Synchronized (X.21)

Strap Off

Clocks not Synchronized (EIA-530 and V.35)

LK5: DTE Signal Ground-to-Frame Ground (with Resistor)

This setting determines whether or not the DTE signal ground

(DB-25 pin 7) is connected to frame ground (pin 1) by way of a 100
ohm resistor. This connection is recommended in the EIA-530 specifi-
cation as a current limiter for ground fault events.

LK5

Setting

Strap On

SGND-to-FGND Connection Made

Strap Off

SGND-to-FGND Connection Broken

3.2.2  CONFIGURING THE MODEL 1000RCM70375 REAR CARD

The Model 1000RCM70375 DB15/Coax Ohm rear card has two

configuration jumpers (LK1 & LK2). Figure 5 (below) shows the loca-
tions of the jumpers on the 75 Ohm rear card.

9

10

Figure 5. Jumper Locations for the Model 1000RCM70375 Rear Card

LK1

LK2

120 OHM REAR CARD JUMPERS

Jumper

Function

Factory Default

LK1

RX Pin 2 to GND

Strap Off

LK2

RX Shield (Pin 3) to GND

Strap Off

LK3

TX Pin 4 to GND

Strap Off

LK4

Clock Synchronization

Strap Off 

LK5

(DTE) SGND to FGND 

Strap On

Содержание 2703RC

Страница 1: ...l us how you like this product and how we can meet your product needs today and in the future Web http www patton com Sales E mail sales patton com Support E mail support patton com Phone Sales 301 97...

Страница 2: ...installation If the Model 2703RC does cause interference to radio or television reception which can be determined by turning the power off or removing the card the user is encouraged to try to correc...

Страница 3: ...nal interface to be adapted to X 21 using a special DTE cable available from Patton The Model 2703RC is designed to mount in Patton s 2U high 16 slot rack chassis or 2 4 8 slot Cluster Boxes These hav...

Страница 4: ...Switches S1 S8 The configuration switches on S1 S8 may be used to set data inversion the DTE bit rate and clocking modes Default settings of S1 through S8 are shown in the table below Descriptions of...

Страница 5: ...d is marked THIS SIDE UP FOR V 35 on one side of the board other side 4 Plug the interface board into the 20 pin header socket with the appropriate interface pointed UP and with the arrow pointing tow...

Страница 6: ...ermines whether clocks are common or separate Separate non synchronized clocks are used for the EIA 530 V 35 ter minal interface Common synchronized clocks are used for the X 21 terminal interface If...

Страница 7: ...assis and provides diagrams for wiring the interface connections correctly 4 1 THE MODEL 1000R16 RACK CHASSIS The Model 1000R16 Rack Chassis Figure 6 below has sixteen device card slots plus its own p...

Страница 8: ...and power card replacement information 4 2 INSTALLING THE MODEL 2703RC INTO THE CHASSIS The Model 2703RC is comprised of a front card and a rear card The two cards meet inside the rack chassis and plu...

Страница 9: ...coax cables is isolated from system earth ground 4 4 CONNECTION TO THE TERMINAL DEVICE The Model 2703RC rear cards are wired as Data Circuit Terminating Equipment DCE and are designed to connect dire...

Страница 10: ...in evaluating the operation of the local Model 2703RC Any data sent to the local Model 2703RC in this test mode will be echoed returned back to the user device For example char acters typed on the key...

Страница 11: ...e 1000RPEM DC DC Rear Power Entry Module 1000RPSM 48A 48V Front Power Supply Module 1000RPEM V 120 240V CE Compliant Rear Power Entry Module 1000RPSM V 120 240V CE Compliant Front Power Supply Module...

Страница 12: ...baluns electronic data switches data line surge protectors multiplex ers transceivers hubs print servers and much more We produce these prod ucts at our Gaithersburg MD USA facility and can custom ma...

Отзывы: