49
APPENDIX E
(continued)
PATTON NETLINK-E1™ MODEL 2701RC
EIA-530 INTERFACE PIN ASSIGNMENT
DB-25 Female Connector, Terminal Interface
Pin #
Signal
1
FG (FrameGround)
2
TD (Transmit Data-A, DTE Source)
3
RD (Receive Data-A, DCE Source)
4
RTS (Request to Send-A, DTE Source)
5
CTS (Clear to Send-A, DCE Source)
6
DSR (Data Set Ready-A, DCE Source)
7
SGND (Signal Ground)
8
CD (Carrier Detect-A, DCE Source)
9
RC/ (Receiver Clock-B, DCE Source)
10
CD/ (Carrier Detect-B, DCE Source)
11
XTC/(External Transmitter Clock-B, DTE Source)
12
TC/(Transmitter Clock-B, DTE Source)
13
CTS/(Clear to Send-B, DCE Source)
14
TD/(Transmit Data-A, DTE Source)
15
TC(Transmitter Clock-B, DCE Source)
16
RD (Receive Data-A, DCE Source)
17
RC (Receiver Clock-A, DCE Source)
18
LL (Local LIne Loop)
19
RTS/(Request to Send-B, DTE Source)
20
DTR (Data Terminal Ready-A, DTE Source)
22
DSR/ (Data Set Ready-B, DCE Source)
23
DTR/(Data Terminal Ready-B, DTE Source)
24
XTC (External Transmitter Clock-A, DTE Source)
25
TM (Test Mode)
50
APPENDIX E
(continued)
PATTON ELECTRONICS MODEL 2701RC
INTERFACE PIN ASSIGNMENT
X.21 Interface
(DB-15 Female Connector)
(DTE /DCE Configuration)
Pin #
Signal
1. . . . . . . . . . . . Frame Ground
2. . . . . . . . . . . . T (Transmit Data-A)
3. . . . . . . . . . . . C (Control-A)
4. . . . . . . . . . . . R (Receive Data-A)
5. . . . . . . . . . . . I (Indication-A)
6. . . . . . . . . . . . S (Signal Element Timing-A)
7 . . . . . . . . . . . BT (Byte Timing-A)
8 . . . . . . . . . . . SGND (Signal Ground)
9 . . . . . . . . . . . T/ (Transmit Data-B)
10 . . . . . . . . . . . C/ (Control-B)
11 . . . . . . . . . . . R/ (Receive Data-B)
12 . . . . . . . . . . . I/ (Indication-B)
13 ........................S/ (Signal Element Timing-B)
14 .......................BT/ (Byte Timing-B)