2.0  GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product.

This product has been thoroughly inspected and tested and is
warranted for One Year parts and labor.  If any questions or problems
arise during installation or use of this product, please do not hesitate to
contact Patton Electronics Technical Support at (301)-975-1007.

2.1  FEATURES

• Bi-directionally converts synchronous RS-232 to V.35

• Data rates to 384 Kbps, full or half duplex

• Transparent to protocol

• No AC power or batteries required

• DCE/DTE strap selectable

• DB-25 and M/34 connectors with integral 6 ft cable (Model 2020)

• Dual DB-25 connectors with integral 6ft cable (Model 2020-25)

• DB-25 and M/34 connectors in one plastic enclosure (Model 2020N)

• Circuitry housed in ultra-miniature case

• Made in the USA.

2.2  DESCRIPTION

The Model 2020 and 2020N RS-232 to V.35 converters let a

synchronous RS-232 device communicate bi-directionally with a
synchronous V.35 device.  The Model 2020/2020N require no AC power
or batteries to operate and supports data rates to 384 Kbps.  Operating
full or half duplex, the Model 2020 passes all necessary clocking and
control signals, and is transparent to protocol.

The Model 2020 connects directly to the synchronous RS-232

interface using a male or female DB-25 connector.  A male or female
M/34 connector at the end of an integral 6 ft cable plugs into the V.35
device.  The Model 2020-25 substitutes a male or female DB-25 on the
V.35 interface.  The Model 2020N house both DB-25 and M/34
connectors within the same enclosure.

An internal DCE/DTE strap allows the user to configure the Model

2020/2020N  as "DCE to DTE" or  "DTE to DCE".  In most cases, this
eliminates the need for special crossover cables.  Housed in an ultra-
miniature case measuring only 2.66" x 2.10" x 0.73", the Model 2020
fits easily into tight locations.  The Model 2020N measures a tiny 3.20”L
x 2.10”H x 0.90”W.

4

3

3.0  CONFIGURATION

The Model 2020/2020N is designed to be easy to use.  In most

cases you will not need to configure the Model 2020/2020N  in 

any

way: just plug it in and go!  The Model 2020 is transparent to protocol,
including data rate and clocking method.  the only configuration you
may need to do is for DTE/DCE orientation.  This procedure is
described below.  

3.1  SETTING DCE/DTE ORIENTATION

The Model 2020/2020N  installs between DTE devices such as

terminals and host computers,  and DCE devices such as modems,
multiplexers and CSU/DSUs.  Most often the DTE device will be RS-
232, and the DCE device will be V.35.  Therefore, the default
DCE/DTE setting for the Model 2020 is RS-232 DCE to V.35 DTE
,
based on how the Model 2020 "sees" its 

own

orientation.  For example,

if the Model 2020 sees its own RS-232 port as DCE, it will want to plug
into an RS-232 DTE device such as a terminal.

If you need to reverse the DCE/DTE orientation of the Model 2020

so that the RS-232 port is DTE and the V.35 port is DCE, follow the
step-by-step instructions below (note: it is not possible to configure the
Model 2020/2020N so that both ports are DTE or DCE).

3.1.1  OPENING THE CASE

The DCE/DTE strap on the Model 2020/2020N  is located on the

PC board.  To access the PC board you will need to open the plastic
case.  

1.   Simply insert a small flathead screw driver or similar tool 

between the DB-25 connector and the lip of the case as
shown in Figure 1, below.  

Figure 1. Inserting the screw driver

RS-232

Interface

Содержание 2020

Страница 1: ...USER MANUAL MODEL 2020 and MODEL 2020N Interface Powered RS 232 to V 35 Converters C E R T I F I E D An ISO 9001 Certified Company...

Страница 2: ...s which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If...

Страница 3: ...configure the Model 2020 2020N as DCE to DTE or DTE to DCE In most cases this eliminates the need for special crossover cables Housed in an ultra miniature case measuring only 2 66 x 2 10 x 0 73 the M...

Страница 4: ...rap is set so that it sees its DB 25 port as DCE It wants to plug into the DB 25 port of a terminal or other DTE The arrow pointing toward the cable at the rear of the PC board shows the orientation o...

Страница 5: ...B 25 carries the same signals as the M 34 but is pinned according to the RS 530 Standard Please refer to Appendix B for specific pin out information APPENDIX A MODEL 2020 AND 2020N SPECIFICATIONS Inte...

Страница 6: ...y H Data Terminal Ready K M P Transmitted Data A S Transmitted Data B U Terminal Timing A W Terminal Timing B Y Transmit Timing A AA Transmit Timing B Signal Ground B Clear To Send D Data Carrier Dete...

Страница 7: ...tom manufacture products for your unique needs We would like to hear from you Please contact us in any of the following ways to tell us how you like this product and how we can meet your product needs...

Отзывы: