5.2  POWER-UP

Apply AC power to the Model 1226 by plugging the separate AC

power adapter into the rear panel outlet of the Model 1226, and then
into an acceptable AC power outlet.  Make sure you connect the parallel
side first, then the line side.  There is no power switch on the Model
1226; when the “Power” LED is lit, the Model 1226 is powered up.
When the local and remote Model 1226s are both powered up and
passing data normally, the following LED conditions will exist:

PWR = Green

TD & RD = Red or blinking red/green

CTL IN & CTL OUT = Green

Status = Blinking green

APPENDIX A

SPECIFICATIONS

Parallel Interface:

DB-25 female

Data Rate:

Up to 57.6 Kbps

Range:

Up to 14 miles

Transmission: 

Full duplex over 4-wire shielded or 
unshielded twisted pair

Line Interface:

RJ-11, RJ-45 or terminal block

Surge Protection:  

600W power dissipation at 1mS and 
response time less than 1.0pS

LED Indicators:  

Power, TD, RD, Ctl-In, Ctl-Out, Status

Optical Isolation:  

2500 V RMS

Power:

10 V AC transformer (110 or 220)

Dimensions:

5.90”l x 4.17”w x 1.61”h

Weight:

Approximately 16 oz.

11

12

LED Codes

●  ●  

●  

———

●  ●  

●  

———

Computer is sending data

●  

———

●  

———

●  

———

Unit is powered up and initialized;

computer is not sending data

●  ●  

———

●  ●  

———

Parallel device is connected; 

computer is not sending data

●  

●  

———

●  

●  

———

Printer not ready, data held in buffer

●  ●  ●  ●  

———

●  ●  ●  ●

Computer ignoring flow control, data lost

Key:

Blink

Short pause

———

Long pause

Содержание 1226

Страница 1: ...USER MANUAL MODEL 1226 Parallel Short Range Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1226 B Doc 104031UB Revised 08 13 99...

Страница 2: ...ber may be obtained from Patton Electronics Technical Service at 301 975 1007 Packages received without an RMA number will not be accepted Patton Electronics technical staff is also available to answe...

Страница 3: ...proper setting The ON and OFF positions are shown in Figures 1 and 2 3 3 1 1 DETAILED SWITCH SETTINGS This section provides detailed information about the function of each DIP switch and lists all po...

Страница 4: ...on your Model 1226 Next you will need to configure your computer s settings If you are using DOS type the following command at the C prompt MODE COM2 9600 n 8 1 p If you are not using DOS call Patton...

Страница 5: ...CV 5 XMT 6 GND 6 RCV 7 GND 8 NC When connecting two Model 1226s it is necessary to use a cross over cable The diagram below shows how a crossover cable should be constructed for an environment where b...

Страница 6: ...hat indicate the condition of the modem and communication link Figure 5 shows the front panel location of each LED Following Figure 5 is a description of each LED s function The Power LED glows solid...

Страница 7: ...NDIX A SPECIFICATIONS Parallel Interface DB 25 female Data Rate Up to 57 6 Kbps Range Up to 14 miles Transmission Full duplex over 4 wire shielded or unshielded twisted pair Line Interface RJ 11 RJ 45...

Страница 8: ...uter 6 Data Bit 5 Computer 5 Data Bit 4 Computer 4 Data Bit 3 Computer 3 Data Bit 2 Computer 2 Data Bit 1 LSB Computer 1 Data Strobe Active LOW Computer SOURCE TRANSMITTER RECEIVER DB 25 SOURCE Common...