2-1
S
ETUP
& I
NSTALLATION
Caution, Disconnect the POWER Before Removing The Cover
Vorsicht, Befor Deckung Abnehmen Mach Strom Zu.
Power Connection
Before connecting the 1206P (CTS ME-X.21) to a AC power source the top cover must be
installed and secured with the supplied #8-32 screws. The unit is supplied with a 110/220VA
voltage switch, turn the switch with a coin or screw driver to the appropriate voltage for your
country. EXAMPLE: In the United States of
America; set to 110VA. The unit is supplied
with a IEC power connector next to the
voltage select switch, plug the power cord
into the connector until it is firmly seated.
You may now connect the power cord into
your AC outlet.
Factory Configuration Switch Settings
The 1206P (CTS ME-X.21) is configured prior to shipment with the switches set to the
following default positions:
Switch 1 - 2, 3, 5 and 6 to
OFF
, 1 and 4 to
ON
.
Baud Rate = 64Kbps
Switch 2 - 1, 3, 4 and 6 to
OFF
, 2, and 5 to
ON
.
Port 1 IND Delay = 0
Port 2 IND Delay = 0
JP1 - JP3 always connected
JP4 - Open
HS Option
JP7 - Open
JP8 - Open
JP9 - Open
JP10 - Open
If the system application requires one of more of the default settings to be
changed, it will be necessary to remove the top cover of the enclosure to access
and change the DIP switches or Jumpers located on the printed circuit board.
CHAPTER 2 - S
ETUP
AND
I
NSTALLATION
CAUTION
: F O R C O N T I N U E D P R O T E C T I O N A G A I N S T R I S K
F I R E , R E P L A C E O N L Y
W I T H S A M E T Y P E
A N D R A T I N G F U S E .
110 / 220 VA S witch
Fuse Drawer
P O R T 1
IEC Power Connector
110
220
100-120V
0.16ASB,250V
TO.16A,250V
200-240V
0.08ASB,250V
TO 0.08A,250V
*
*
Switch fuse for 100-120V (.16ASB, 250V) or 200-240V
(.8ASB, 250V) as noted on rear of unit.