Controlling DSR

Data Terminal Ready (DTR) on each port is routed to the Data Set Ready (DSR) pin of the
other port.  DSR can be configured to follow the DTR or can be forced to be active all the time.

Power

110 or 220 Volt operation is provided by a convenient switch located on the rear panel of the
1205P (CTS ME-V.35).  Simply install the proper fuses (110VAC - .16ASB, 250V or 220VAC
- .8ASB, 250V) and power plug for the country of use and select the proper line voltage and
the unit is ready for operation.

Approvals

Safety approvals for UL & CSA have been granted allowing the Modem Eliminator.  FCC Part
15 class A emissions approvals insure the Modem Eliminator will not interfere with any of the
other equipment in your data center. The Model 1205P Serieshas been tested and found to
comply with the limits for a Class A computing device in accordance with the specifications in
Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection from
such interference in a commercial installation.

CE NOTICE: The CE symbol on your Patton Electronics equipment indicates that it is in
compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage
Directive (LVD) of the Union European (EU).  A Certificate of Compliance is available by
contacting Technical Support.

Available Options

1205P is available in both stand-alone subset or rack-mountable versions (1205PRC).
Various configurations of the interface are also available from the factory.  The 1205PRC fits
into the Model 1010R16 16 Card Rack Assembly.

Содержание 1205P

Страница 1: ...MODEM ELIMINATOR V 35 1 2 0 5 P CTS ME V 35 INSTALLATION AND OPERATIONS MANUAL Doc 113001UA Part 07M1205P A Copyright 2000 Patton Electronics Co All Rights Reserved An ISO 9001 CertifiedCompany...

Страница 2: ...nty period shall be two years from the date of shipment of equipment Patton s sole obligation under its warranty is limited to the repair or replacement of the defective equipment provided it is retur...

Страница 3: ...radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a resident...

Страница 4: ...ration Switch Settings 2 1 Disassembly 2 2 Installation 2 2 Equipment Grounding JP4 2 2 CTS Delay Port 1 SW2 1 2 2 2 CTS Delay Port 2 SW2 4 5 2 3 DSR Control Port 1 SW1 6 2 3 DSR Control Port 2 SW1 5...

Страница 5: ...Port Rates up to 2 048Mbps are provided by the internal baud rate generator The generator will provide clocks for both terminal and insure the data is synchronized with the RX Clock in bothdirections...

Страница 6: ...pprovals insure the Modem Eliminator will not interfere with any of the other equipment in your data center The Model 1205P Serieshas been tested and found to comply with the limits for a Class A comp...

Страница 7: ...let Factory Configuration Switch Settings The 1205P CTS ME V 35 is configured prior to shipment with the switches set to the followingdefaultpositions Switch 1 2 and 3 to OFF 1 4 5 and 6 to ON Baud Ra...

Страница 8: ...n AC power source Installation Select an appropriate location accessible to and within six feet of an AC power outlet The outlet must have a ground pin receptacle for product warranty Straight Through...

Страница 9: ...to ON to select DSR on Port 1 switching in response to DTR from Port 2 switching Set SW1 position 5 to OFF to set DSR on Port 2 to be forced ON DCD Control Port 1 SW2 6 SW2 position 6 selects DCD cont...

Страница 10: ...ate Selection SW1 1 2 3 4 Selection of internal rates is provided by configuration of SW1 positions 1 through 4 and JP7 through JP10 if the High Speed Option has been installed by the factory The foll...

Страница 11: ...be utilized by setting SW1 positions 1 through 4 to ON JP10 Installed JP7 JP8 JP9 Removed 256K JP9 Installed JP7 JP8 JP10 Removed 512K JP8 Installed JP7 JP9 JP10 Removed 1 024M JP7 Installed JP8 JP9 J...

Страница 12: ...rce 100 120 200 240VAC 50 to 60Hz 0 16 0 08A switchable Environmental Oper Temp 32 to 122 F 0 to 50 C Rel Humidity 5 to 90 non condensing Altitude 0 to 10 000 feet Dimensions Height 1 75 inches 4 44 c...

Страница 13: ...CS CD TC RC JP10 JP9 JP8 JP7 2 048Mbps HS Option 1 024Mbps HS Option 512Kbp s HS Option 256Kbp s HS Option Install Only One Jumper to Select the Required Rate ONLY ON THE OPTIONAL HS VERSION Port 1 1...

Отзывы: