background image

112001UA

i

I

NSTALLATION

 A

ND

 O

PERATIONS

 M

ANUAL

Patton Electronics Co.

1200P

PROPRIETARY NOTICE

The information contained herein is proprietary and confidential to Patton

 

Electronics Co.  Any reproduction or

redistribution of this publication, in whole or in part, is expressly prohibited unless written authorization is given
by Patton

 

Electronics Co.

WARRANTY NOTICE

WARRANTIES:  Patton

 

Electronics Co. (hereafter referred to as Patton) warrants that its equipment is free

from any defects in materials and workmanship.  The warranty period shall be two years from the date of
shipment of equipment.  Patton’s sole obligation under its warranty is limited to the repair or replacement of the
defective equipment, provided it is returned to Patton, transportation prepaid, within a reasonable period.  This
warranty will not extend to equipment subjected to accident, misuse, alterations or repair not made by Patton
or authorized by Patton in writing.

PUBLICATION NOTICE

This manual has been compiled and checked for accuracy.  The information in this manual does not constitute a
warranty of performance.  Patton reserves the right to revise this publication and make changes from time to
time in the content thereof.  Patton assumes no liability for losses incurred as a result of out-of-date or
incorrect information contained in this manual.

RADIO AND TV INTERFERENCE

The Patton MSDs generate and use radio frequency energy, and if not installed and used properly—that is, in
strict accordance with the manufacturer’s instructions—may cause interference to radio and television
reception.  The Patton MSDs have been tested and found to comply with the limits for Class A computing
devices in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to
provide reasonable protection from such interference in a commercial installation.  However, there is no
guarantee that interference will not occur in a particular installation.  If the Patton MSDs do cause interference
to radio or television reception, which can be determined by disconnecting the cables, the user is encouraged to
try to correct the interference by one or more of the following measures: moving the computing equipment
away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a
different AC outlet (such that the computing equipment and receiver are on different branches).

CE NOTICE

The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the electromagnetic
Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the European Union (EU). A Certificate of
Compliance is available by contacting Technical Support.

SERVICE

All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics.  All
returns must have a Return Materials Authorization number on the outside of the shipping container. This
number may be obtained from Patton Electronics Technical Support at:

tel:  (301) 975-1007;

email:  [email protected];

or, www:  http://www.patton.com.

NOTE:  Packages received without an RMA number will not be accepted.
Patton Electronics’ technical staff is also available to answer any questions that might arise concerning the
installation or use of your Patton MSDs.  Technical Support hours: 8AM to 5PM EST, Monday through Friday.

Copyright© 2000 Patton Electronics Co., All Rights Reserved

Содержание 1200P

Страница 1: ...c 112001UA Part 07M1200P A MODEM ELIMINATOR RS 232 1200P CTS ME V 24 INSTALLATION AND OPERATIONS MANUAL B Copyright 2000 Patton Electronics Co All Rights Reserved AnISO 9001 CertifiedCompany May 15 20...

Страница 2: ...Doc 112001UA Part 07M1200P A MODEM ELIMINATOR RS 232 1200P CTS ME V 24 INSTALLATION AND OPERATIONS MANUAL B Copyright 2000 Patton Electronics Co All Rights Reserved AnISO 9001 CertifiedCompany...

Страница 3: ...ve been tested and found to comply with the limits for Class A computing devices in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable pro...

Страница 4: ...112001UA ii INSTALLATION AND OPERATIONS MANUAL Patton Electronics Co 1200P...

Страница 5: ...N CHAPTER 2 SETUP AND INSTALLATION Power Connection 2 1 Factory Configuration 2 1 Installation 2 1 CTS Delay SW2 1 2 2 2 DSR Control SW2 3 4 2 2 DCD Control SW2 5 6 2 3 Clocking SW1 1 2 3 4 5 2 3 Equi...

Страница 6: ...is transparent to the data Terminal devices can be separated up to 50 feet away from the 1200P CTS ME V 24 depending on the baud rate selected The unit is supplied with two DB 25 female connectors fo...

Страница 7: ...ated You may now connect the power cord into your AC outlet Factory Configuration The 1200P CTS ME V 24 is configured prior to shipment with the switches and jumpers in the following default positions...

Страница 8: ...Active SW2 position 4 selects DSR control for the terminal connected to J3 Settting SW2 position 4 to ON will select DSR on J3 to switch in responce to DTR from J2 switching Setting SW2 position 4 OFF...

Страница 9: ...ion is accomplished via SW1 positions 1 thru 5 Set position 1 to ON ON ON ON ON and 2 to OFF OFF OFF OFF OFF for CLK1 Set position 1 to OFF OFF OFF OFF OFF and 2 to ON ON ON ON ON for CLK2 Table I out...

Страница 10: ...imensions Height 1 75 inches 4 44 cm Width 8 90 inches 22 60 cm Length 10 00 inches 25 40 cm Weight 2 50 lbs 1 1 35 Kg Appendix Applications RS 232 Sync or Async Terminal to Terminal interconnection C...

Страница 11: ...A 2 Appendix 1200P Signal Routing Diagram J2 J3 1 Frame Gnd 4 RTS 8 DCD 5 CTS 1 Frame Gnd 4 RTS 8 DCD 5 CTS 6 DSR 20 DTR 6 DSR 20 DTR 8V 8V 8V 8V 2 TXD 2 TXD 3 RXD 3 RXD 15 TXC 17 RXC 15 TXC 17 RXC 7...

Страница 12: ...B 7622 Rickenbacker Drive Gaithersburg MD 20879 Sales 301 975 1000 Support 301 975 1007 Web Address www patton com...

Отзывы: