The Model 1193RC is equipped with eight DIP switches, which

allow configuration of the unit for a wide variety of applications.  This
section describes location of the switches and explains all possible
configurations.

3.1  CONFIGURE THE HARDWARE DIP SWITCHES 

The 8 external dip switches are accessible from the underside of

the Model 1193RC (See Figure 2 below).   

Figure 3 shows the orientation of the DIP switches in the

“ON” and “OFF” positions.  

5

Figure 3. Close up of configuration switches 

Figure 2. Underside of Model 1193RC, showing location of the DIP switches

Front

Rear

3.1.1 Configure the Model 1193RC

Switches S1 through S8 may be used to configure clocking modes

and line coding.  Default settings of the switches are shown in the table
below. A description of the switch options follows the table.

Switches S1 and S2: Clock Mode

Use switches S1 and S2 to determine clock mode of the 1193RC.

S1    S2    Setting                 Description

On

On

Internal

Transmit clock generated internally

On

Off

Receive Recover   Transmit clock derived from the Receive 

data on the fiber side.

Off

On     Network

Transmit clock derived from G.703/G.704 

equipment interface

Off

Off

Internal use only

Switch S3 and S4:  Line Coding Options

Use switches S3 and S4 to determine whether the G.703/G.704 line

coding is HDB3 or AMI (for older telecommunications equipment). The
line coding must be the same line coding prescribed by the NAP
(Network Access Provider).  Most applications will use HDB3.

High Density Bipolar 3 (HDB3):  In HDB3 coding, the transmitter
deliberately inserts a bipolar violation when excessive zeros in the
data stream are detected. The receiver recognizes these special vio-

6

Position

Function

Default Setting

S1

Clock Source

ON      Internal

S2

Clock Source

ON      Clock

S3

Line

OFF    HDB3

S4

Coding

OFF

S5
S6

Reserved for Future Applications

  N/A

S7
S8

OFF

ON

Note: The Model 1193RC units are intended to work in pairs. Set the
clock modes for the Model 1193 units with one end of the link set for
receive recover and the other end set for either internal or network.

OFF

S1

ON

OFF

Содержание 1193RC

Страница 1: ...1193RC G 703 G 704 to Single mode Fiber Rack Mount Modem Card Part 07M1193RC A Doc 017141UA Revised 05 04 01 SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com An ISO 9001 C...

Страница 2: ...the following lost profits lost savings and incidental or consequen tial damages arising from the use of or inability to use this product Patton Electronics specifically disclaims all other warrantie...

Страница 3: ...his product please do not hesitate to con tact Patton Electronics Technical Support at 301 975 1007 2 1 FEATURES ITU G 703 G 704 E1 transport over Single mode fiber Full duplex operation over a single...

Страница 4: ...2 Setting Description On On Internal Transmit clock generated internally On Off Receive Recover Transmit clock derived from the Receive data on the fiber side Off On Network Transmit clock derived fro...

Страница 5: ...l 1001RCM703SC with SC fiber connector and 1001RCM703FC with FC fiber connector See Figure 4 at upper right Each of these inter face cards support one fiber connector two BNC and one RJ 48C line conne...

Страница 6: ...ower card replacement information 4 4 0 0 I IN NS ST TA AL LL LA AT TI IO ON N This section describes the functions of the Model 1001R14 rack chassis tells how to install front and rear Model 1193RC S...

Страница 7: ...section describes both options After selecting the appropriate connec tion set the internal jumpers as described in section 3 2 of this manual 4 2 1 Connecting theTwisted Pair 120 Ohm to G 703 G 704 N...

Страница 8: ...synchro nization process should take approximately 5 seconds Any time one of the Model 1193RCs lose power i e in a lightning storm the local and remote units will re synchronize before they can resum...

Страница 9: ...tern generator See section 5 2 3 on how to use the built in 511 511E pattern generator 3 If the BER test equipment indicates a fault and the Local Analog Loopback test was successful for both Model 11...

Страница 10: ...OS LED indicates the presense of coding errors NS The red NS LED indicates that the sig nal on the fiber side is too weak to be detected ER Flashing red ER LED indicates errors in 511 test pattern TM...

Страница 11: ...240V Front Power Supply Module 1001RPEM RDC DC Rear Power Entry Module 1001RPSM R48A 48V Front Power Supply Module 1001R14P Rack 14 Slot 2U Chassis Only 1001R14P R48V Rack 14 Slot 2U w Dual Universal...

Отзывы: