3.1.1 Switch Set S1

The configuration switches on S1 set clock source, RTS/CTS

delay, carrier control, loopback tests. The default settings are summa-
rized in the table above.

Switches S1-1 and S1-2: Clock Source

Switches S1-1 and S1-2 are set in combination to determine the

source of timing for the Model 1094.

S1-1

S1-2

Setting

On

On

Internal

On

Off

Receive recover

Off 

On

External transmit clock

Off

Off

Not a valid setting

Switch S1-3: RTS/CTS Delay

Switch S1-3 is used in combination to determine the amount of

delay between the time RTS is activated and the 1094 activates the
CTS.

S1-3

Function

On 

Short delay (1-4 ms)

Off

Long delay (8-20 ms)

Switch S1-4: LDL Control

Switch S1-4 determines whether the frontt panel switch can acti-

vate a Local Digital Loopback (LDL) diagnostic test.

S1-4

Function

On

LDL Control Enabled

Off

LDL Control Disabled

Switch S1-5: Carrier Control

The setting for switch S1-5 determines whether the carrier is “con-

stantly on” or “controlled by RTS”. This setting allows for operation in
switched carrier or hardware handshaking applications.

S1-5

Setting

On

Controlled by RTS

Off

Constantly ON

Switch S1-6: DTE Control of RDL

The setting for switch S1-6 determines whether DTE control of

remote-digital loopback test is enabled or disabled. If DTE control is
disabled, the RDL test can only be initiated by the front panel switch.

S1-6

Setting

On

DTE control enabled

Off

DTE control disabled

Switch S1-7: DTE Control of LAL

The setting for switch S1-7 determines whether DTE control of

local analog loopback test is enabled or disabled. If DTE control is dis-
abled, the LAL test can only be initiated by the front panel switch.

S1-7

Setting

On

DTE control enabled

Off

DTE control disabled

S1 SUMMARY TABLE

Position

Function

Factory Default

S1-1

Clock Source*

On

S1-2

Clock Source*

On 

S1-3

RTS/CTS Delay

On

Short Delay

S1-4

LDL

Off

Disabled

S1-5

Carrier Control

Off

Constant

S1-6

DTE Control of RDL

Off

Disabled

S1-7

DTE Control of LAL

Off

Disabled

S1-8

V.54 Enable/Disable

Off

Enabled

*See Note in SWITCH SET S1 (Below) for X.21 Clock Sources

}

Internal

NOTE:

When an X.21 QuickConnect™ module is installed in 

one or both base units, one base unit

must be configured for 

receive recover clock source. The particular application will 
dictate which unit must be configured for receive recover clock
source.

Содержание 1094

Страница 1: ...1094 KiloModem 768TM High Speed Baseband Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1094 C Doc 032031UC R evised 04 13 99 C E R T I F I E D An ISO 9001...

Страница 2: ...which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interfer ence will not occur in a particular installation If...

Страница 3: ...rn generator and seven front panel LED indicators Data integrity is enhanced by automatic equalization and gain control The Model 1094 also incorporates transformer isolation and surge protection to g...

Страница 4: ...ications S1 5 Setting On Controlled by RTS Off Constantly ON Switch S1 6 DTE Control of RDL The setting for switch S1 6 determines whether DTE control of remote digital loopback test is enabled or dis...

Страница 5: ...onnections 4 1 CONNECTION TO THE TWISTED PAIR INTERFACE The Model 1094 supports communication between two terminal devices at distances to 4 9 miles 7 9 km and data rates to 768 kbps There are two ess...

Страница 6: ...sp the two thumbscrews and gently pull the module from the unit Apply equal force to the thumbscrews to keep the module straight during the removal process Installing the New QuickConnect Module 1 Mak...

Страница 7: ...configuration of the X 21 port Reinstall the module according to the instructions in Section 4 2 1 4 3 CONNECTION TO THE POWER SOURCE The Model 1094 is available with three power supply options The St...

Страница 8: ...em s carrier is being received DTR Will glow green to indicate that the Data Terminal Ready signal from the terminal is active ER Will glow red to indicate the likelihood of a Bit Error in the receive...

Страница 9: ...test equipment indicates a fault and the Local Analog Loopback test was successful for both Model 1094s you may have a problem with the line between the Model 1094s You should inspect the line for pro...

Страница 10: ...working properly 3 This test can be done by one operator by first activating the local analog loop or remote digital loop APPENDIX A PATTON ELECTRONICS MODEL 1094 SPECIFICATIONS Transmission Format S...

Страница 11: ...6 Use of twisted pair with a resistance greater than the above specifications may cause a reduction in maximum distance obtainable Functionality should not be affected Many environmental factors can a...

Страница 12: ...Line Loop 19 RTS Request to Send 20 DTR Data Transfer Rate 21 DL Remote Digital Loop 22 DSR Data Set Ready 23 DTR Data Transfer Rate 24 XTC External Transmit Clock 25 TM Test Mode APPENDIX D PATTON E...

Страница 13: ...Signal 1 Frame Ground 2 T Transmit Data A 3 C Control A 4 R Receive Data A 5 I Indication A 6 S Signal Element Timing A 7 BT Byte Timing A 8 SGND Signal Ground 9 T Transmit Data B 10 C Control B 11 R...

Отзывы: