background image

3.1.1  CONFIGURATION SWITCH SET “S1”

The eight DIP switches on pack S1 set data rate, clock source,

async/sync mode and carrier control method.  Factory default settings
are summarized in Figure in the table below.  Descriptions of all
possible S1 switch settings, including the Patton factory default
settings, are found on on pages 4 and 5. 

S1-1 through S1-4:  Data Rate Setting

Switches S1-1 through S1-4 are set in combination to determine

the asynchronous and synchronous data rate for the Model 1045RC.  

Model 1045RC:

S1-1

S1-2

S1-3

S1-4

Setting

Off

Off

On

Off

32.0 kbps

Off

On

Off

Off

56.0 kbps

On

Off

Off

Off

64.0 kbps

S1-5 and S1-6:  Clock Source

Switches S1-5 and S1-6 are set in combination to determine the

transmit clock source for the Model 1045RC.

S1-5

S1-6

Setting

On

On

Internal transmit clock

Off

On

Receive recover clock

On

Off

External transmit clock

S1-7:  Carrier Control Method

5

The setting for switch S1-7 determines whether the carrier is

“constantly on” or “controlled by RTS”.  This setting allows for operation
in switched carrier, multipoint and/or hardware handshaking
applications.

S1-7

Setting

Off

Constantly on

On

Controlled by RTS

S1-8:  V.52 and V.54 Diagnostic Test

To reset the V.54 circuit, set switch S1-8 to the “ON” position, then

back to the “OFF” position.

S1-8

Setting

Off

Enable (Normal Operation)

On

Test Disabled

3.1.2   CONFIGURATION SWITCH SET “S2”

The eight DIP switches on pack S2 set RTS/CTS delay, word

length, extended signaling rate, async/sync mode and remote test
initiation.  Factory default settings are summarized in the table below.
Descriptions of all possible S1 switch settings, including the Patton
factory default settings, are found on on pages 6  and 7.

6

S1 SUMMARY TABLE

Position

Function

Factory Default

S1-1

Data Rate

Off

S1-2

Data Rate

On

S1-3

Data Rate

Off

S1-4

Data Rate

Off

S1-5

Clock Source

On

S1-6

Clock Source

On

S1-7

Carrier Control

Off

Constantly On

S1-8

V.52/V.54 Tests

Off

Enable

56 Kbps

Internal

}

}

S2 SUMMARY TABLE

Position

Function

Factory Default

S2-1

RTS/CTS Delay

On

S2-2

RTS/CTS Delay

On

S2-3

Word Length

Off

S2-4

Word Length

Off

S2-5

Extended Signaling

Off

-2.5% to +1%

S2-6

Async/Sync

Off

Sync

S2-7

DTE Control of LAL

On

Enable

S2-8

DTE Control of RDL

On

Enable

10 bits

}

7 ms

}

Содержание 1045RC

Страница 1: ...Powered High Speed Short Range Modem Rack Mount Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1045RC B Doc 054051UB Revised 3 14 97 C E R T I F I E D An IS...

Страница 2: ...ar installation If the Model 1045RC does cause interference to radio or television reception which can be determined by turning the power off or removing the card the user is encouraged to try to corr...

Страница 3: ...iode surge suppressors The Model 1045RC is designed to mount in Patton s 2U high 19 rack chassis This 16 card chassis has a switchable 120 240 VAC power supply optional 48 VDC and mounts cards in a mi...

Страница 4: ...peration in switched carrier multipoint and or hardware handshaking applications S1 7 Setting Off Constantly on On Controlled by RTS S1 8 V 52 and V 54 Diagnostic Test To reset the V 54 circuit set sw...

Страница 5: ...ng mode S2 6 Setting On Asynchronous Off Synchronous Note in asynchronous mode the Clock Source must be set to Internal S1 5 On S1 6 On 7 S2 7 RS 232 V 35 Initiation of Local Analog Loopback Test The...

Страница 6: ...ward the front of the PC board 9 3 2 REAR CARD CONFIGURATION The Model 1045RC has four rear interface card options DB 25 RJ 11 DB 25 RJ 45 M 34 RJ 11 and M 34 RJ 45 see Figure 5 below Each of these op...

Страница 7: ...ignal Ground and frame ground In the open position pin 1 or pin B is lifted from frame ground JB4 Position 1 2 SGND DB 25 pin 7 or M 34 pin B and FRGND Connected Position 2 3 SGND DB 25 pin 7 or M 34...

Страница 8: ...lled cards 4 2 INSTALLING THE MODEL 1045RC INTO THE CHASSIS The Model 1045RC is comprised of a front card and a rear card The two cards meet inside the rack chassis and plug into each other by way of...

Страница 9: ...ment are NOT acceptable For further information about acceptable wire grades please refer to the diagram in appendix B Point to Point Twisted Pair Connection The 6 position RJ 11 and 8 position RJ 45...

Страница 10: ...LED will blink sporadically 17 4 If the BER test indicates no errors are present move the V 52 toggle switch to the left thus activating the 511 E test with periodic errors If the test is working pro...

Страница 11: ...ch on both Model 1045RCs must be turned on 2 If the test indicates no errors are present move the V 52 toggle switch to the left thus activating the 511 E test with errors present If the test is worki...

Страница 12: ...he above data rate distance table as a general guideline only 21 APPENDIX C MODEL 1045RC FACTORY REPLACEMENT PARTS The Patton Model 1045RC rack system features interchangeable rear cards power cords f...

Страница 13: ...m 1045RC 9 Receive Clock B From 1045RC 11 External Clock B To 1045RC 12 Transmit Clock B From 1045RC To 1045RC Data Term Ready DTR 20 DIRECTION CCITT V 35 EIA 530 INTERFACE DB 25 DIRECTION To 1045RC E...

Отзывы: