APPENDIX A

PATTON MODEL 1040 SPECIFICATIONS

Transmission Format:  

Sync. or async., full or half duplex

Transmission Line: 

Unconditioned twisted pair 19 - 26 
AWG

Clocking: 

Internal, external or receive 
loopback

Interfaces: 

EIA RS-232, CCITT V.24 

Data Rates: 

1.2, 1.8, 2.4, 3.6, 4.8, 7.2, 9.6, 
14.4, 19.2, 28.8, 38.4 Kbps (switch 
selectable)

Isolation: 

Minimum 1500 V RMS via 

isolation transformers

Control Signals:  

Constantly “on” or controlled by 
RTS

RTS/CTS Delay:  

No delay, 7mS, 53mS

Connectors: 

DB-25 male or female on RS-232 
side; RJ-11, RJ-45 or terminal 
block with strain relief on line side

Power Supply: 

None required; uses power from 
EIA data and control signals

Surge Protection:  

Compliant with IEC 801.5 level 2, 
1kV 

Temperature Range: 

0-60°C (32-140°F)

Altitude:  

0-15,000 feet

Humidity:  

5 to 95% noncondensing

Dimensions:  

3.0” x 2.1” x .81” 
(7.6 x 5.3 x 2.1 cm)

Weight:  

2 oz. (56.7g)

APPENDIX B

PATTON MODEL 1040 CABLE RECOMMENDATIONS

The Patton Model 1040 operates at frequencies of 20kHz or less

and has been performance tested by Patton technicians using twisted-
pair cable with the following characteristics:

Wire Gauge

Capacitance

Resistance

19 AWG/.9mm 83nf/mi or 15.72 pf/ft. .0163 Ohms/ft.
22 AWG/.6mm 83nf/mi or 15.72 pf/ft. .0326 Ohms/ft.
24 AWG/.5mm 83nf/mi or 15.72 pf/ft. .05165 Ohms/ft.

To gain optimum performance from the Model 1040, please keep

the following guidelines in mind:

• 

Always

use 

twisted pair

wire—this is not an option.

• Use twisted pair wire with a capacitance of  20pf/ft or less.

• Avoid twisted pair wire thinner than 26 AWG (i.e. avoid higher 

AWG numbers than 26)

• Use of twisted pair with a resistance greater than the above 

specifications may cause a reduction in maximum distance 
obtainable.  Functionality should not be affected.

• Environmental factors too numerous to mention can affect the 

maximum distances obtainable at a particular site.  Use “maximum 
distance” figures as a 

general guideline only

.

20

19

24 AWG 

(0.5 mm)

26 AWG

(0.4 mm)

19 AWG

( 0.9 mm)

38,400 6.0(9.7) 4.5(7.2) 2.5(4.0)
19,200 9.0(14.5) 6.5(10.5) 4.0(6.4)

9,600 10.0(16.1) 7.0(11.3) 5.0(8.0)
4,800 11.0(17.7) 8.0(12.9) 6.0(9.7)
1,200 12.0(19.3) 10.0(16.1) 6.0(9.7)

Data Rate

(bps)

Model 1040 Distance Table in Miles (km)

Wire Gauge 

Содержание 1040

Страница 1: ...NUAL MODEL 1040 Self Powered Universal Short Range Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1040 B Doc 054011UB Revised 4 29 98 An ISO 9001 Certified...

Страница 2: ...ed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If the Model 1040 do...

Страница 3: ...Support at 301 975 1007 2 1 FEATURES Switch selectable carrier control Synchronous or asynchronous operation No AC power or batteries required Data rates to 38 4 Kbps Distances to 12 miles 19 2 km Poi...

Страница 4: ...Kbps On On Off On 4 8 Kbps Off On Off On 7 2 Kbps On Off Off On 9 6 Kbps Off Off Off On 14 4 Kbps On On On Off 19 2 Kbps Off On On Off 28 8 Kbps On On Off Off 38 4 Kbps SW1 5 and SW1 6 Clock Source S...

Страница 5: ...enabled To reset the V 54 circuit set switch SW2 8 to the ON position then back to the OFF position SW2 8 Setting On Disabled Off Enabled SW1 8 Carrier Control Method The setting for switch SW1 8 dete...

Страница 6: ...environment see Figure 5 The signal pin relationships are shown on the table on the following page RJ 1 1 SIGNAL RJ 45 SIGNAL 1 GND 1 N C 2 RCV 2 GND 3 XMT 3 RCV 4 XMT 4 XMT 5 RCV 5 XMT 6 GND 6 RCV 7...

Страница 7: ...mit poles on the terminal block The Model 1040 is not polarity sensitive so either wire may connect to either pole 5 Connect the other pair of wires to the two RCV receive poles on the terminal block...

Страница 8: ...er side This completes cable installation 4 2 CONNECTION TO THE RS 232 INTERFACE Once you have connected the twisted pair wires correctly simply plug the Model 1040 directly into the DB 25 port of the...

Страница 9: ...eration both front panel switches should be in the normal center position To operate a test mode see Section 5 3 5 2 LED STATUS MONITORS The Model 1040 features 2 front panel LEDs that indicate the co...

Страница 10: ...remote Model 1040 and looped back To perform an RDL test follow these steps A Activate RDL This may be done in two ways first by moving the front panel toggle switch UP to RDL Second by raising pin 21...

Страница 11: ...rformance tested by Patton technicians using twisted pair cable with the following characteristics Wire Gauge Capacitance Resistance 19 AWG 9mm 83nf mi or 15 72 pf ft 0163 Ohms ft 22 AWG 6mm 83nf mi o...

Страница 12: ...To Model 1040 5 CTS Clear to Send From Model 1040 6 DSR Data Set Ready From Model 1040 7 SG Signal Ground 8 DCD Data Carrier Detect From Model 1040 9 DCV To Model 1040 To Model 1040 Data Term Ready DT...

Отзывы: