2.0  GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product.

This product has been thoroughly inspected and tested and is
warranted for One Year parts and labor.  If any questions or problems
arise during installation or use of this product, please do not hesitate to
contact Patton Electronics Technical Support at (301) 975-1007.

2.1  FEATURES

• Supports point-to-point data rates from 1.2 to 19.2 Kbps

• Internal, crystal controlled clock

• Transformer isolation guards against ground looping

• Range to 11 miles

• Full duplex operation

• Custom VLSI chip with separate filter for each data rate

• No AC power or batteries required

• Miniature size

• High speed surge protection (Model 1020S only)

2.2  DESCRIPTION

The Patton Electronics Model 1020 miniature, synchronous short

range modem uses the latest in VLSI technology to combine high-
quality data transmission with compact size.  The Model 1020 does not
require any AC power or batteries to operate, and communicates up to
11 miles in point-to-point environments.  

Supporting full duplex transmission over two twisted pairs, the

Model 1020 has a crystal controlled internal clock.  Data rates are
switch selectable from 1200 to 19,200 bps.  The Model 1020’s custom
VLSI chip uses a separate filter for each data rate, rather than a single
“compromise” filter.  Transformer isolation allows the Model 1020 to
operate between buildings without data disruption due to ground
potential differences.  

The Model 1020S is a surge protected version of the Model 1020,

incorporating Silicon Avalanche Diodes that provide 600 watts of
protection per wire.

3.0  CONFIGURATION

The Model 1020 provides four configuration switches which allow

selection of RTS/CTS delay and data rates.  This section describes
switch locations and explains all possible switch configurations. 

3.1  SWITCH LOCATIONS

For your convenience, all configuration switches are located on a

SIP (single in-line package) mounted on the PC board.  Figure 1 shows
the location of the SIP with respect to other PC board components.  For
instructions on opening the Model 1020 case, see Section 4.1.2.

Figure 2 shows the orientation of the configuration switches,

including the ON/OFF position.

4

3

P AT

TO

N

PE068

XXXX

1

2

3

4

ON

OFF

Figure 1.  Model 1020 PC board showing switches

Figure 2. Close-up of configuration switches 

Control

Switches

Terminal Block

Patton

VLSI chip

Isolating

Transformers

Содержание 1020

Страница 1: ...20S Synchronous Short Range Modem with Transformer Isolation SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1020 C Doc 041011UC Revised 4 20 98 C E R T I F I E D...

Страница 2: ...d to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If the Model 1020 doe...

Страница 3: ...1020 has a crystal controlled internal clock Data rates are switch selectable from 1200 to 19 200 bps The Model 1020 s custom VLSI chip uses a separate filter for each data rate rather than a single...

Страница 4: ...INTERFACE The Model 1020 supports data only communication between two RS 232 devices at distances to 11 miles and data rates to 19 2 Kbps There are two essential requirements for installing the Model...

Страница 5: ...should be followed when using RJ 45 connectors or a combination of the two SIGNAL PIN COLOR COLOR PIN SIGNAL GND 1 Blue White 6 GND RCV 2 Yellow Red 4 XMT XMT 3 Green Black 5 RCV XMT 4 Red Yellow 2 RC...

Страница 6: ...nnecting the shield at the computer end only A ground wire is not necessary for proper operation of the Model 1020 7 When you finish connecting the wires to the terminal block the assembly should rese...

Страница 7: ...e closed Repeat the process for the other side This completes cable installation 4 2 CONNECTION TO THE RS 232 INTERFACE Once you have connected the twisted pair wires correctly simply plug the Model 1...

Страница 8: ...RD Receive Data From Model 1020 4 RTS Request to Send To Model 1020 5 CTS Clear to Send From Model 1020 6 DSR Data Set Ready From Model 1020 7 SG Signal Ground 8 DCD Data Carrier Detect From Model 102...

Отзывы: