4.0  INSTALLATION

Once you have properly configured the DTE/DCE switch, you are

ready to connect the Model 1010A to your system.  This section tells
you how to properly connect the Model 1010A to the twisted pair and
RS-232 interfaces, and how to operate the Model 1010A.

4.1  CONNECTION TO THE TWISTED PAIR INTERFACE

The Model 1010A supports data-only communication between two

RS-232 devices at distances to 8.5 miles and data rates to 115.2 Kbps.
There are two essential requirements for installing the Model 1010A:

1) These units work in 

pairs.  Therefore, you must have one Model

1010A at each end of a two twisted pair interface.

2) To function properly, the Model 1010A needs two twisted pairs of

metallic wire.  These pairs must be 

unconditioned, dry metallic wire,

between 19 and 26 AWG (the higher number gauges may limit distance
somewhat).  Standard dial-up telephone circuits, or leased circuits that
run through signal equalization equipment, are 

not acceptable.

For your convenience, the Model 1010A is available with three

different twisted pair interfaces:  RJ-11 jack, RJ-45 jack and terminal
blocks with strain relief.

4.1.1  TWISTED PAIR CONNECTION USING RJ-11 OR RJ-45

The RJ-11 and RJ-45 connectors on the Model 1010A's twisted pair

interface are pre-wired for a standard TELCO wiring environment.  The
signal/pin relationships are shown below:

RJ-11

SIGNAL

RJ-45

SIGNAL

1...................GND*

1 .................N/C

2...................RCV-

2 .................GND*

3...................XMT+

3 .................RCV-

4...................XMT-

4 .................XMT+

5...................RCV+

5 .................XMT-

6...................GND

6 .................RCV+
7 .................GND
8 .................N/C

4

10.  BEND the top half of the case as necessary to place it over the

strain relief assembly.  Do not snap the case together yet.  

11.  Insert one captive screw through a saddle washer, then insert

the captive screw with the washer on it through the hole in the DB-25
end of the case.  Snap that side of the case closed.  Repeat the
process for the other side.  This completes cable installation.

4.2   CONNECTION TO THE RS-232 INTERFACE 

Once you have configured the Model 1010A for DTE or DCE and

connected the twisted pair wires correctly, all that remains is to plug the
1010A directly into the DB-25 port of the RS-232 device.  After doing
so, remember to insert and tighten the two captive connector screws. 

(Note: If you must use a cable to connect the Model 1010A to the
RS-232 device, make sure it is a 

straight through cable of the shortest

possible length—we recommend 6 feet or less). 

4.3   OPERATING THE MODEL 1010A 

Once the Model 1010A is properly installed, it should operate

transparently—as if it were a standard cable connection.  Operating
power is derived from the RS-232 data and control signals; there is no
"ON/OFF" switch.  All data signals from the RS-232 interface are
passed straight through.  All control signals from the RS-232 interface
are looped back. 

(Note:  If your system requires 

hardware flow control, you will need the

Patton Model 1012 or Model 1060 Short Range Modem.  Call Patton
Customer Service at 301-975-1007 for more information). 

+RCV- G -XMT+

+RCV- G -XMT+

+RCV- G -XMT+

9

Содержание 1010A

Страница 1: ...USER MANUAL MODEL 1010A Miniature High Speed Short Range Modem with Transformer Isolation SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M1010A A Doc 039011UA Revised 11 8 95...

Страница 2: ...ion The Model 1010A has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to...

Страница 3: ...nchronous RS 232 devices communicate between buildings over two twisted pair Supporting asynchronous data rates to 115 2 Kbps the Model 1010A derives the necessary power for operation from the data an...

Страница 4: ...e Data Communications Equipment and transmit data on pin 3 3 DCE DTE DCE DTE Switch Surge Suppressors DCE DTE Terminal Block Transformers APPENDIX B SPECIFICATIONS Transmission Format Asynchronous ful...

Страница 5: ...NAL RJ 45 SIGNAL 1 GND 1 N C 2 RCV 2 GND 3 XMT 3 RCV 4 XMT 4 XMT 5 RCV 5 XMT 6 GND 6 RCV 7 GND 8 N C 4 10 BEND the top half of the case as necessary to place it over the strain relief assembly Do not...

Страница 6: ...blocks The following instructions will tell you how to open the case connect the bare wires to the terminal blocks and fasten the strain relief collar in place so that the wires won t pull loose cont...

Страница 7: ...ich color is positive and which color is negative 5 Connect the other pair of wires to RCV and RCV receive positive and negative on the terminal block again making careful note of which color is posit...

Отзывы: