APPENDIX B

PATTON MODEL 1009 CABLE RECOMMENDATIONS

The Patton Model 1009 operates at frequencies of 20kHz or less

and has been performance tested by Patton technicians using twisted-
pair cable with the following characteristics:

Wire Gauge

Capacitance

Resistance

19 AWG/.9mm

83nf/mi or 15.72 pf/ft.

.0163 Ohms/ft.

22 AWG/.6mm

83nf/mi or 15.72 pf/ft.

.0326 Ohms/ft.

24 AWG/.5mm

83nf/mi or 15.72 pf/ft.

.05165 Ohms/ft.

To gain optimum performance from the Model 1009 please keep the

following guidelines in mind:

• 

Always use twisted pair wire—this is not an option.

• Use twisted pair wire with a capacitance of  20pf/ft or less.

• Avoid twisted pair wire thinner than 26 AWG (i.e. avoid higher 

AWG numbers than 26)

• Use of twisted pair with a resistance greater than the above 

specifications may cause a reduction in maximum distance 
obtainable.  Functionality should not be affected.

• Environmental factors too numerous to mention can affect the 

maximum distances obtainable at a particular site.  Use “maximum 
distance” figures as a general guideline only

.

APPENDIX C

PATTON MODEL 1009 PIN ASSIGNMENTS

(D-Sub 9 Connector, DCE Configuration)

1- (FG)Data Carrier Detect

From Model 1009

2- (RD) Receive Data

From Model 1009

3- (TD) Transmit Data

To Model 1009

4- (DTR)Data Terminal Ready

To Model 1009

5- (SG) Signal Ground

-

From Model 1009

Data Set Ready (DSR) - 6

To Model 1009

Request To Send (RTS) - 7

From Model 1009

Clear to Send (CTS) - 8

DIRECTION

STANDARD "DCE" CONFIGURATION

DIRECTION

11

12

Содержание 1009

Страница 1: ...USER MANUAL MODEL 1009 1009S Ultra miniature Asynchronous DB 9 Short Range Modem...

Страница 2: ...h are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If the M...

Страница 3: ...ls The Model 1009S uses the latest in bi directional clamping transient suppressors to guard itself and connected equipment against data line transients For surge handling capability the Model 1009S i...

Страница 4: ...e wires to the terminal blocks and fasten the strain relief collar in place so that the wires won t pull loose Note The terminal block configurations are different for the 1009M male and 1009F female...

Страница 5: ...the diagram below 8 Place the 2 halves of the strain relief assembly on either side of the telephone wire and press together very lightly Slide the assembly so that it is about 2 inches from the term...

Страница 6: ...9 is properly installed it should operate transparently as if it were a standard cable connection Operating power is derived from the RS 232 data and control signals there is no ON OFF switch All data...

Страница 7: ...isted pair wire thinner than 26 AWG i e avoid higher AWG numbers than 26 Use of twisted pair with a resistance greater than the above specifications may cause a reduction in maximum distance obtainabl...

Страница 8: ...ture Web http www patton com Sales E mail sales patton com Support E mail support patton com Phone Sales 301 975 1000 Phone Support 301 975 1007 Fax 301 869 9293 Mail Patton Electronics Company 7622 R...

Отзывы: