Patton electronics 1004 Скачать руководство пользователя страница 5

4.0  INSTALLATION

Once the Model 1004 is properly configured, it is ready to connect

to your system.  This section tells you how to properly connect the
Model 1004 to the twisted pair and RS-232 interfaces, and how to
operate the Model 1004.

4.1  TWISTED PAIR CONNECTION

The Model 1004 supports data-only communication between two

RS-232 devices at distances to 9.4 miles and data rates to 115.2 Kbps.
There are two essential requirements for installing the Model 1004:   

1.

These units work in 

pairs.  Therefore, you must have one Model

1004 at each end of a two twisted pair interface.  In multipoint
environments, there must be one Model 1004 at the RS-232 host
and one at each RS-232 terminal.

2.

To function properly, the Model 1004 needs two twisted pairs of
metallic wire.  These pairs must be 

unconditioned dry metallic

wire, between 19 and 26 AWG (the higher number gauges may
limit distance).  Standard dial-up telephone circuits, or leased cir-
cuits that run through signal equalization equipment, are 

not

acceptable.

For your convenience, the Model 1004 is available with several

different twisted pair interfaces:  RJ-11 jack, RJ-45 jack, terminal
blocks with strain relief and dual modular jacks (for multipoint daisy-
chaining).

4.1.1  TWISTED PAIR CONNECTION USING TERMINAL BLOCKS

If your application requires you to connect one or two pairs of bare

wires to the Model 1004, you will need to open the case to access the
terminal blocks.  The following instructions will tell you how to open the
case, connect the bare wires to the terminal blocks and fasten the
strain relief collar in place so the wires won't pull loose.

1.  You should already have the case open for the configuration

procedure.  If not, see Section 3.2.   

2.  Strip the outer insulation from the twisted pair(s) about one

inch from the end.  

7

3.  Strip the insulation on each of the twisted pair wires about .25”.

4.  In a two pair circuit, connect 

one pair of wires to XMT+ and

XMT- (transmit positive and negative) on the terminal block, making
careful note of which color is positive and which color is negative.  

5. Connect the 

other pair of wires to RCV+ and RCV- (receive

positive and negative) on the terminal block, again making careful note
of which color is positive and which color is negative.

Ultimately, you will want to construct a two pair crossover cable that

makes a connection with the two Model 1004s as shown below.

6.  In a single pair circuit, use 

only the transmit (XMT) pair as

shown below:

7. If there is a shield around the telephone cable, it may be con-

nected to “G” on the terminal block.  To avoid ground loops, we recom-
mend connecting the shield at the computer end only.  A ground wire is
not necessary for proper operation of the Model 1004.

8

XMT+--------------------------------------------------RCV+
XMT- --------------------------------------------------RCV-
G ----------------------

G

RCV+--------------------------------------------------XMT+
RCV- --------------------------------------------------XMT-

To Shield (Optional)

}

One Pair

}

One Pair

XMT+--------------------------------------------------XMT+
XMT- --------------------------------------------------XMT-

Содержание 1004

Страница 1: ...USER MANUAL SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M1004 C Doc 047011UC Revised 8 10 95 MODEL 1004 and 1004S High Speed Multipoint Short Range Modem...

Страница 2: ...be returned freight prepaid and insured to Patton Electronics All returns must have a Return Materials Authorization number on the outside of the shipping container This number may be obtained from Pa...

Страница 3: ...t ting causes the Model 1004 to behave like Data Communications Equipment and transmit data on pin 3 3 DCE DTE DCE DTE Switch 2 Wire 4 Wire Switch Surge Suppressors 1004S only Terminal Block Control S...

Страница 4: ...RTS CTS Delay 0mS 8mS SW1 2 Echo Enable Echo Off Echo On SW1 3 Carrier Control Constantly On Controlled by RTS SW1 4 Impedance High 120K Ohm Low 120 Ohm SW2 2 wire 4 wire 2 wire 4 wire SW 1 4 Impedanc...

Страница 5: ...quires you to connect one or two pairs of bare wires to the Model 1004 you will need to open the case to access the terminal blocks The following instructions will tell you how to open the case connec...

Страница 6: ...act our technical support We have strain relief assemblies to accommodate most cable diameters RCV G XMT RCV G XMT 9 10 Insert the strain relief assembly and wire into the slot in the bottom half of t...

Страница 7: ...ll vary based upon the number of drops data rate wire gauge etc Call Technical Support for specific distance estimates 12 4 1 2 TWISTED PAIR CONNECTION USING RJ 11 OR RJ 45 The RJ 11 and RJ 45 connect...

Страница 8: ...Figure 5 Daisy chain wiring for Model 1004 host and slaves With the dual modular units you won t need to build cumbersome Y cables for your daisy chain application Simply use a crossover cable to go...

Страница 9: ...r No external power required uses ultra low power from EIA data and control signals Size 2 66 x 2 10 x 0 73 15 APPENDIX B RS 232 PIN CONFIGURATIONS 1 FG Frame Ground 2 TD Transmit Data To Model 1004 3...

Страница 10: ...APPENDIX C BLOCK DIAGRAM 17...

Отзывы: