5
Patron E3 - 12/00
4. MAINTENANCE
WARNING!
NEVER SERVICE THE HEATER WHILE IT IS PLUGGED IN, RUNNING OR
HOT. SEVERE BODILY INJURE OR ELECTRIC SHOCK MAY OCCUR.
ONLY QUALIFIED PERSONS ARE ALLOWED TO OPEN HEATER FOR SERV-
ICE. NO USER-SERVICEABLE PARTS INSIDE.
•
Keep heater clean. Use pressurized air to blow fan blades clean. Note! Use
moderate pressure to avoid damage to fan blades
•
Inspect heater before and after each use
•
The fan motor is sealed and has permanently lubricated bearings
5. STORAGE
When not in use, the heater must be disconnected from power source, cleaned of
dust and stored in a dry place.
The power supply cord should be loosely wound around the handle of the heater.
6. TECHNICAL SPECIFICATIONS
MODEL
PATRON E3
Heat output
BTU/hr
10,200 (3,000 W)
Air flow
CFM
205 (350 m³/h)
Electric connection
V ac / Hz
240 / 60, single phase
Amperage draw
A
12.5
Power cord
3×16 AWG
Plug
NEMA 6-15P
Extension cord
min. 3×16 AWG
Ambient thermostat
Temp.range 32 ... 100 °F (0 ... 40 °C)
Length
inches
11.8 (300 mm)
Width
inches
10.2 (260 mm)
Height
inches
15.2 (385 mm)
Weight
lbs
20.3 (9.2 kg)