manualshive.com logo in svg
background image

E1.5 PRODUCT MANUAL

RENTQUIP USA INC.  |  1-800-818-1199  |  WWW.PATRONPRODUCTS.COM

OPERATION

REVIEW AND UNDERSTAND ALL WARNINGS IN THIS MANUAL. THEY ARE ESSENTIAL FOR SAFE USE 

OF THE HEATER.

FOLLOW ALL LOCAL CODES

This heater is for use on 120 volts

The cord has a plug as show in the figure

The type of outlet is a 120-volt grounding outlet. When properly installed, it provides a ground connection 

through the cord to the heater to protect the operator from electric shock.

TO START HEATING:

1.  Place the heater on a stable and level surface. Make sure that no explosive or combustible fumes or dust 

are present 

 

MINIMUM CLEARANCES FROM COMBUSTABLE MATERIALS

OUTLET = 6 feet

SIDES = 1 foot

TOP = 2 feet

REAR = 2 feet

FLOOR = COMBUSTABLE

2.  Connect power cord of heater into 120 V / 60 Hz power source. See paragraph “Technical specifications” in 

this manual for correct amperage rating

3.  Set the room thermostat from “heat off” position to a temperature above the ambient room temperature by 

turning the knob. Note! The heater will start heating only if the thermostat “calls for heat” meaning that it is 
set to higher than prevailing ambient temperature

4.  The heater will now operate automatically, controlled by the thermostats

TO STOP HEATING

1.  Turn the room thermostat into position “heat off”
2.  Let the fan cooldown heater for 2-3 minutes
3.  Disconnect the power supply plug

NOTE!

THE HEATER IS EQUIPPED WITH AN OVERHEAT LIMIT SWITCH WHICH MAY CAUSE THE HEATER TO 

STOP. CHECK AND REMOVE THE CAUSE FOR OVERHEATING BEFORE RESTARTING.

RENTQUIP USA INC.  |  1-800-818-1199  |  WWW.PATRONPRODUCTS.COM

Содержание E1.5

Страница 1: ...READ AND UNDERSTAND THIS MANUAL BEFORE ASSEM BLING STARTING OR SERVICING THE HEATER IMPROPER USE OF HEATER CAN CAUSE SERIOUS INJURY KEEP THIS MANUAL FOR FUTURE REFERENCE FOR PROFESSIONAL USE ONLY RENT...

Страница 2: ...ll into a bathtub or other liquid container 7 Do not run cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away from traffic area and where it will not be tripped...

Страница 3: ...er than those provided by an authorized PATRON service THERE ARE NO OBLIGATIONS OR LIABILITIES ON THE PART OF PATRON PRODUCTS INC FOR CON SEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE US...

Страница 4: ...TLET 6 feet SIDES 1 foot TOP 2 feet REAR 2 feet FLOOR COMBUSTABLE 2 Connect power cord of heater into 120 V 60 Hz power source See paragraph Technical specifications in this manual for correct amperag...

Страница 5: ...Inspect heater before and after each use The fan motor is sealed and has permanently lubricated bearings STORAGE When not in use the heater must be disconnected from power source cleaned of dust and...

Страница 6: ...Mantle 6 20220 Ambient Thermostat 7 20220 Ambient Thermostat 8 21200 Overheat Limit Switch 9 42256 Heating Element 10 14040 Fan Motor 11 16040 Fan Blade 12 36910 Strain Reliever 13 36701 Terminal Blo...

Страница 7: ...mostat thermostat ambiant 20220 TO overheat limit switch disjoncteur de surchauffe 21200 X1 terminal block bloc terminal 36701 X2 grounding lug bloc terre X3 power cord plug fil electrique fiche 30330...

Страница 8: ...PATRON PRODUCTS A DIVISION OF RENTQUIP 1 800 818 1199 www patronproducts com...