background image

Align Flanges

Optional 2nd Remote UV Light 

Installation Instructions

The optional Remote UV Light works with 

the PCO system for enhanced disinfection, 

reduced system maintenance, and improved 

indoor air quality.

2

 Air Handler Interior Surface Installation

1. 

Determine the optimal position  

for placement of the 

UV lamp.

2.

 Use a utility knife to cut a slit in the insulation 

on the interior surface.

3.

 Place the magnetic 

“Z” bracket

 directly on the 

metal surface or remove the magnet and hard-

mount the bracket using the 

self-tapping 

screws

 provided. Use foil tape to close the cut 

in the insulation.

4.

 Use plastic 

quick-nuts

 to attach the  

UV lamp

 to the 

“Z” bracket

 as shown.

IMPORTANT!

•  PCO Dual lamps are wired in series - both must be connected for lamps to light

•  Only qualified technicians should install this product

•  Install in accordance with relevant building codes

•  Read instructions carefully including safety warnings

2. 

3. 

4. 

P

3

 Coil “A” plate or Duct Installation

1. 

Snap the 

“Z” bracket

 apart by 

bending.

2.

 Drill a 1” hole in the "A"-plate 

or duct then attach the smaller 

piece of the bracket using the 

self-tapping screws

.

3.

 Insert the 

UV lamp

 into the hole 

then use the plastic 

quick-nuts

 

to attach the 

UV lamp

 to the 

“Z” bracket

 as shown.

1. 

2. 

3. 

P

1

 Installation Notes

Before installing the Remote UV Light it is necessary to 

determine the optimal mounting location inside the air 

system. First, look for the area with the heaviest mold 

growth. Also consider a location that will allow the 

germicidal UV light to shine on the greatest surface area. 

Some typical mounting locations:

A

 Supply-side duct

B

 At the blower

C

 Across top of coils

D

 Coil face

E

 Coil "A" plate

F

 Return-side duct

Important:

 some materials inside the air system (including 

filter media, flex duct, wiring etc.) may not be UV light resistant. 

Use the optional UV shield (part #TUV-SHIELD-LPC) or cover 

the materials with reflective tape.

WARNING

PROTECT EYES FROM UV LIGHT

TURN OFF UNIT OR DISCONNECT

BEFORE SERVICING

Mounting Options

A

B

C

D

D

E

F

Electronic  
Power Supply

H

 or 

I

Optional 2nd 

UV Lamp

N

O

5

 Remote UV Lamp Connection

1. 

When all the other components are properly installed connect the UV Lamp 

cable to the 

PCO

 Power supply cable. 

2.

 Make sure the flanges are aligned and then push the connectors firmly 

together. A tight connection ensures a proper water-resistant seal.

2. 

1. 

7

  Lamp Replacement

The germicidal UV lamp in the Remote UV Light needs to be replaced periodically. A 

TUVL-115P lamp should be replaced every year. The TUVL-215P should be replaced 

every 2 years. Note: UV lamps will continue to emit visible light but lose germicidal 

effectiveness over time. You can upgrade to a 2 year with your existing power supply.

TUVL-115P

(1 Year)

TUVL-215P

(2 Year)

CAUTION!

UV lamps contain small amounts of mercury - dispose of lamps in accordance with 

local environmental regulations. For more information visit www.lamprecycle.org

4

 Remote UV Light Configuration

IMPORTANT! 

Only the Patriot PCO Dual model has the 

electrical capacity and attached cable for the optional 

Remote UV Light. Simply connect the lamp lead to the 

power cable on the left side of the Patriot PCO Power Unit. 

 

To add a second UV light to an existing Patriot PCO system 

that is not a Dual model install a separate Patriot UV system.

6

 Sight Glass Installation

1. Find a suitable location on the outside 

of the duct-work near the UV Lamp 

installation and apply the warning/lamp 

replacement sticker.

2. Drill a ½”  hole through the orange circle 

on the sticker. Press the UV safety viewport 

into hole.

3. Turn on the power and use the sight glass to 

confirm that the UV Lamp is operating.