A warning sign shall be fitted to every point where persons may 
gain ready access to the conductors. 
Where an electric animal fence crosses a public pathway, a non-
electrified gate shall be incorporated in the electric animal fence 
at that point or a crossing by means of stiles shall be provided. 
At any such crossing, the adjacent electrified wires shall carry 

warning signs. 
Any part of an electric animal fence that is installed along a 
public road or pathway shall be identified at frequent intervals by 
warning signs securely fastened to the fence posts or firmly 

clamped to the fence wires. 

• 
• 

The size of the warning sign shall be at least 4x8” (100x200 mm). 
The background colour of both sides of the 
warning sign shall be yellow. The inscription on 
the sign shall be black and shall be either: 
or the substance of “CAUTION: Electric Fence”. 

 

• 

The inscription shall be indelible, inscribed on both sides of the 
warning sign and have a height of at least 1” (25 mm). 

 

Ensure that all mains-operated, ancillary equipment connected 
to the electric animal fence circuit provides a degree of isolation 
between the fence circuit and the supply mains equivalent to 

that provided by the electric fence charger. 
Protection from the weather shall be provided for the ancillary 
equipment unless this equipment is certified by the 
manufacturer as being suitable for use outdoors, and is of a type 

with a minimum degree of protection IPX4. 

 

cêÉèìÉåíäó=~ëâÉÇ=
èìÉëíáçåëLqêçìÄäÉëÜççíáåÖ=

eçï=Çç=f=áåÅêÉ~ëÉ=ÑÉåÅÉ=îçäí~ÖÉ\=

Sometimes recent extensions to your fence, a poor fence layout, 

or soil conditions may be causing inadequate voltage.  
To check the electric fence charger, disconnect it from the fence 
and the ground system. Measure the voltage across the electric 
fence charger terminals with a digital voltmeter. If the voltage is 
less than 6 kV your electric fence charger may be faulty. Go to 

www.patriotglobal.com

 for more details. 

eçï=Çç=f=äçÅ~íÉ=Ñ~ìäíë\=

The most common cause of low voltage is faults on the fence 
line. Faults can be arcing faults that often make a clicking sound 
that can be heard when walking along a fence line. These are 
most often caused by faulty insulators or poor connections (loose 
clamps, tied wires or faulty cutout switches) and are normally 
fixed by replacing the faulty insulator or repairing the faulty 
connections. Note: Always use specially made joining clamps or 

crimps to secure wire to wire connections on the fence line. 
Another fault type is a short circuit fault. This fault occurs when 
a live fence wire becomes connected in some way to the ground. 
A short circuit fault wastes the power of the electric fence 
charger by drawing energy away from where it is needed, the 
fence line. A common cause of short circuit faults is vegetation 
touching the live wires. Regular clearing of vegetation from the 
fence line will enhance your electric fence charger’s 
performance. The best method to locate a short circuit fault is to 
use a special fault finder. These products save considerable time 

by directing you straight to the fault. Go to 

www.patriotglobal.com

 for more details. 

Another tool used to locate faults is a digital voltmeter. When 
using a digital voltmeter, simply isolate sections of your fence by 
opening cut-out switches or otherwise disconnecting sections of 
the fence from the main lead out wire/s. Measure the voltage 
and determine whether the voltage has improved. If after 
disconnecting a section of the fence you record a significant 
improvement in fence voltage, it is likely that the fault is located 
in the section of fence that you have just isolated. Often a visual 

inspection of the faulty section will reveal the problem.  
By carrying your voltmeter or fault finder when you move around 
the farm you can regularly test your fence system and fix faults 
before they lead to or result in a larger problem. 

qÜÉêÉ=~êÉ=åç=äáÖÜíë=Ñä~ëÜáåÖ=çå=íÜÉ=ÉäÉÅíêáÅ=ÑÉåÅÉ=ÅÜ~êÖÉê=

Check the power supply. If fence charger is connected to line 
power adapter, ensure that the power is switched on. 
Disconnect the power then reconnect the power 30 seconds 

later. 
If fence charger is connected to a 12 V battery, ensure that the 
positive (red) clip is connected to the positive terminal on the 
battery and the negative (black) clip is connected to the negative 
terminal on the battery. 
If the fence charger’s pulse light still does not flash, disconnect 
the battery then reconnect the battery 30 seconds later. Also, 

check the battery voltage. 
If the fence charger still does not operate, refer to your warranty 

conditions. 

pÉêîáÅáåÖ=

This product cannot be serviced. Please refer to your warranty 

conditions. 

pÉêîáÅÉ=çÑ=ÇçìÄäÉ=áåëìä~íÉÇ=~ééäá~åÅÉë=

In a double insulated electric fence charger, two systems of 
insulation are provided instead of grounding. Patriot chargers 

contain no serviceable parts. 

mêçÇìÅí=ëéÉÅáÑáÅ~íáçåë=

 

mR=

mNM=

mOM=

mPM=

Input 
voltage 

12 V,  
45 mA 

12 V, 
90 mA 

12 V, 
170 mA 

12 V, 
300 mA 

Peak 
output 
energy 

up to 0.5 J 

up to 1 J 

up to 2 J 

up to 3 J 

Stored 
energy 

up to 0.7 J 

up to 1.3 J  up to 2.7 J 

up to 4.6 J 

Output 
voltage 

8.0 kV max, 
4.5 kV at 
500 

 

9.7 kV max, 
5.4 kV at 
500 

 

10.5 kV max, 
6.0 kV at 
500 

 

10.5 kV max, 
6.0 kV at 
500 

 

Table represents typical values

Содержание P5

Страница 1: ...G R E A D A L L I N S T R UC T I O NS I N T E L L I G E N T F E N C I N G F O R T H E C O U N T R Y P5 P10 P20 P30 USER MANUAL F L E X I B IL I T Y D E S I G N VA L U E F L E X I B IL I T Y D E S I G...

Страница 2: ...s of Tru Test Corporation Limited No part of this publication may be photocopied reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying r...

Страница 3: ...s Read and follow all instructions provided with the electric fence charger and power adapter Do not use an extension cord with the power adapter Refer to the National Electrical Code ANSI NFPA70 for...

Страница 4: ...d most suitable as a high tension strainer excellent in areas where the soil gets very wet or where heavy frost occurs q o Dairy cattle Sheep Cattle q d For most soil types The animal receives a shock...

Страница 5: ...equipment p Warning Read before use An electric fence can be hazardous when there is a risk of entrapment or entanglement or other hazards exist Serious injury or death may result Take all steps to av...

Страница 6: ...y means of electrically non conductive material or an isolated metal barrier Barbed wire or razor wire shall not be electrified by an electric fence charger A non electrified fence incorporating barbe...

Страница 7: ...cuit fault This fault occurs when a live fence wire becomes connected in some way to the ground A short circuit fault wastes the power of the electric fence charger by drawing energy away from where i...

Страница 8: ...S AV E T H E S E I N S T R UC T I O NS w w w p a t r i ot g l o b a l c o m I N T E L L I G E N T F E N C I N G F O R T H E C O U N T R Y...

Отзывы: