FIVE-YEAR LIMITED WARRANTY

: If, during normal use, this PATRIOT LIGHTING  lighting fixture breaks or fails due 

to a defect in material workmanship within five (5) years from the date of original purchase, simply bring this lighting 

fixture with the original sales receipt back to your nearest MENARDS  retail store. At its discretion, PATRIOT 

LIGHTING  agrees to have the product or any defective part(s) repaired or replaced with the same or similar PATRIOT 

LIGHTING product or part free of charge, within the stated warranty period, when returned by the original purchaser 

with original sales receipt. This warranty; (1) excludes expendable parts including but not limited to light bulbs; (2) does 

not cover damage that has resulted from abuse or misuse; and (3) does not cover any losses, labor, injuries to 

persons/property or costs. This warranty does give you specific legal rights and you may have other rights, which vary 

from state to state.

Questions, problems, missing parts?

Before returning to your retailer, call our customer service at 1-800-887-6326.

Monday – Friday 9:00 a.m. – 5:00 p.m. CST  

TROUBLESHOOTING

R

R

R

CARE AND MAINTENANCE

R

Clean the glass and coated metal surfaces with a non-abrasive cleaner. Do not use any cleaners with chemicals,

solvents or harsh abrasives. Use only a soft dry cloth to dust or wipe the lens area. 

If the light does not work at all:

1. Make sure the switch and circuit breaker are on.

2. Make sure the wiring connection is correct.

3. Make sure the photocell is not exposed to light (if have photocell).

4. Make sure the connections between contact pins of  connector and wires of power adaptor is in good conditions.

Caution:

a. The included cable connectors are to be used only on low voltage power cable with SPT-2W or equivalent 18, 16, 

    14, or 12 AWG cable.

b. The fixture’s cable and connector shall:

    ● Be protected by routing in close proximity to the light fixture, or next to a building structures such as a house or deck.

    ● Not be buried except for a maximum 6 inches (15.2 cm) to connect to the main low voltage cable.

    ● Have a length such that the connector is within six inches (15.2 cm) from the light fixture or a building structure.

c. Do not use cable smaller than listed in chart below.

SELECT CABLE

. Use the chart below to determine the MINIMUM gauge cable to be used, depending on the wattage 

of the power pack. Using large cable will ensure maximum light output.

 

 

 

 

 

   

 

   

 

 

If unable to fix any of the above issues, please consult a certified electrician.

PowerPack Wattage

240-300

12

14-12

16-14-12

18-16-14-12

120-240

60-120

0-60

Minimum Guage Cable