manualshive.com logo in svg
background image

Page 4 of 8

211019

 

ASSEMBLY INSTRUCTIONS  (continued)

ASSEMBLY INSTRUCTIONS  (continued)

Sensitivity of Motion Sensor: 

1. You can adjust the sensitivity of the motion sensor by using the “Sens” selector
     located on the bottom surface of the sensor. (See Fig.5)

2. Adjust motion sensor sensitivity to HIGH (H), MEDIUM (M), or LOW (L) to 
   achieve desired performance.

3. Approximate range for each setting: 30 ft. (L), 50 ft. (M), 70 ft. (H).

Fig. 5

FUNCTION AND OPERATION

Adjusting the Light Head: 

1. Gently grasp the light heads (B) and tilt them up or down, left or right to
    adjust the light coverage area. 
    Keep the light heads (B) at least 1” (25mm) away from the sensor.
   (See Fig. 4)

2. Keep the light heads (B) 30˚ below horizontal to avoid water damage and

    electrical shock.

MODE

TIME

Auto

Link

L

M

H

Test

30s

1min

3min

PC

3H

SENS

Custom

Choose a mode by sliding the switch on the bottom of the sensor.  (See Fig.5)

Note: When power is first applied, the light will turn on to 100% brightness.
The sensor will take 30 seconds to warm up.

   

1. 

TEST MODE (daytime and nighttime operation.)

    ● Slide the Time switch the “Test” position.

    ● The light turns to high-level brightness (5000K) when motion is detected, and stays on as long as the motion 

       continues. 
       Then it revert back to 2700K CCT Color and the low-level brightness (0~50%) as per setting about 5 seconds 
       after motion is no longer detected.

2. 

 AUTO MODE (nighttime operation only)

     ● To “AUTO” mode, 

 

slide

 the 

Time switch to the desired time setting 

        (30s/1min/3min). At dusk, the light turns on to pre-selected low-level 
        brightness (2700K). When motion is detected, the light turns to high-level 
        brightness (5000K) and stays on as long as motion continues. When the 
        motion is no longer detected, the light at high-level brightness (5000K) 
        remains on for the predetermined time you set (30s/1min/3min), then 
        switches back to pre-selected low-level brightness (2700K) automatically. 

     ● The light turns off automatically at dawn.

     Note: You can adjust the low-level brightness(0~50%) by using the low-level brightness(0~50%) knob on
     the backplate (See Fig.6).

3. 

PC MODE (nighttime operation only)

    ● In "PC" mode, the light will turn on at full brightness (5000K) at dusk and remains on until dawn.

4. 

3 HOURS (3H) MODE (nighttime operation only)

    ● In “3H” mode, the light turns to high-level brightness (5000K) at dusk, and stays "ON" for 3 hours, then it turns to

       pre-selected low-level brightness (2700K). It turns to high-level brightness (5000K) when motion is detected, and 
       stays on as long as motion continues. When motion is no longer detected, it remains on for the predetermined 
       shut-off delay time you set (30s/1min/3min), then returns to the pre-selected low-level brightness (2700K) 
       automatically.

     ● The light turns off automatically at dawn.

     Note: You can adjust the low-level brightness(0~50%) by using the low-level brightness(0~50%) knob on
     the backplate (See Fig.6).

B

Fig. 4

Low Level

0%

50%

Fig. 6

Содержание E1205-WH

Страница 1: ...ay 9 00 a m 5 00 p m CST PACKAGE CONTENTS SKU Number 356 9448 356 9449 DUAL HEAD SECURITY LIGHT Model Number E1205 WH E1205 BZ HARDWARE CONTENTS Note Hardware not shown actual size 211019 Wire Connect...

Страница 2: ...140 F 60 C Consult a qualified electrician before installation Do not connect this fixture to an electrical system that does not provide a means for equipment grounding Never use a fixture in a two w...

Страница 3: ...allow moisture to drain Note Make sure sensor head is positioned with control knob facing towards the ground b You can rotate the sensor head up and down to change the coverage area See Fig 1 2 Note R...

Страница 4: ...no longer detected 2 AUTO MODE nighttime operation only To AUTO mode slide the Time switch to the desired time setting 30s 1min 3min At dusk the light turns on to pre selected low level brightness 270...

Страница 5: ...ss the main unit will stop flashing After complete the pairing process any light within the Link group range can send or receive the photo sensor or motion sensor signal from the other light and respo...

Страница 6: ...ction path than motion directly towards it See Fig 10 5 To reduce possible nuisances do not mount the fixture near a heat source like an air conditioner vent or furnace exhaust or in a direction facin...

Страница 7: ...0s 1min 3min setting The TIME switch is in the TEST position The motion sensor may be sensing small animals or automobile traffic Decrease the SENS setting or reposition the motion sensor Decrease the...

Страница 8: ...d you may have other rights which vary from state to state R R R R If unable to fix any of the above issues please consult a certified electrician Questions problems missing parts Before returning to...

Отзывы: