ProMIG series

 DC MMA/TIG/MIG/MAG

 

16. ACCEPTANCE CERTIFICATE 
 

Arc inverter rectifier PATON PROMIG-200/250 
 
Serial number ________________

P

 has been approved for operation. 

 
 
 
Sale date 

”_____”_________________20____

 

 
 
 
 
                                      Stamp here                       _____________________ 

 

 

 

 

 

 

(vendor signature) 

 
 
 

 

 

Содержание ProMIG-200

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ...4 1 5 Welding cycle TIG 4T 18 4 1 6 Function of button on a TIG 4T torch 19 4 2 Preheating current pilot arc function 19 4 3 Arc current fade in function 19 4 4 Arc current fade out function 20 4 5 C...

Страница 5: ...t 0 8 mm at most 1 5 75 2 105 2 5 130 4 205 6 310 4 mm 160 A at most up to 1 0 mm 2 75 2 5 95 4 155 6 230 5 mm 200 A at most 2 5 75 4 125 6 185 ProMIG 250 3 mm 120 A at most 0 8 mm at most 1 5 75 2 10...

Страница 6: ...d wire feeding mechanism as well as availability of KZ 2 slot of world standard EURO type which allows user changing torches at his her own discretion This ProMIG model by PATON is equipped with a uni...

Страница 7: ...automatic automatic automatic Open circuit voltage reduction unit on off on off on off MMA open circuit voltage V 12 70 12 70 12 70 Arc striking voltage V 110 110 110 Rated power consumption kW 5 5 6...

Страница 8: ...t at MMA arc current at TIG arc current MIG MAG welding voltage 3 Source function selection button in the current welding mode 4 Welding mode selection button manual metal arc welding with a stick ele...

Страница 9: ...et of bayonet type a in case of MMAwelding for connection ofelectrode cable very occasionally mass cable can be connected if special electrodes are used b in case of TIG welding only mass cable is con...

Страница 10: ...st direct moisture impact but not against condensate drops ATTENTION Do not switch the machine off immediately after completion of welding works in hot weather or intense welding works in any weather...

Страница 11: ...ge and current consumption of the welding machine see technical data In accordance with safety practices use receptacles with guaranteed earthing 3 MANUAL METAL ARC WELDING MMA WELDING Procedure for m...

Страница 12: ...lues ofmains voltage aroundthe possible minimum value but compromises the quality of the striking moment the machine becomes similar to a transformer source but in some cases this is the only possible...

Страница 13: ...k of burn through but also reduces stability of short arc burning the machine becomes similar to a transformer source The function can also be increased to maximum value for even better stability of s...

Страница 14: ...r more convenient work with basic coated electrodes 13 45 70 it is recommended although not required to set the slope CVS to 1 0V A On the other hand cellulose electrodes 1 4 even require for setting...

Страница 15: ...ost common values of 50 Hz and 50 respectively In order to enable this function it is enough to set pulsing power Po P to a value above zero This parameter is set in percent of current set value of ba...

Страница 16: ...the smaller is the butt withstanding set current the better Remember that a very sharp pointed electrode flashes off very easily at high arc currents due to low heat emission In addition sharpening no...

Страница 17: ...triking without use of high frequency injection units and other similar units However unlike the conventional method it completely eliminates surge current in the moment of striking thus reducing seve...

Страница 18: ...of the wire feeding machine and if they are accidentally short circuited this source will break down Attention If this slot is not used cover it with a rubber cap to prevent clogging After assembly i...

Страница 19: ...rc striking unit high frequency injection units and in built gas valve Cable of the torch control button is connected directly to this unit When the torch button is pressed the control signal is sent...

Страница 20: ...ng the button 5 and holding it for about 5 s The indicator will start flashing thus informing the user that the machine is ready for switching to the next welding mode Ifyou skipped the required weldi...

Страница 21: ...that level t3 until the button is released Only when the button is released for the second time the source switches off and the high frequency injection unit must perform the function of weld zone po...

Страница 22: ...ntrol over welding process in spatial positions other than downhand position as well as during welding of non ferrous metals This function affects directly weld metal dilution and consequently on stab...

Страница 23: ...SEMIAUTOMATIC METAL INERT ACTIVE GAS WELDING MIG MAG Attention In the most general case carbon dioxide 2 is used as shielding gas for welding of iron and aluminium is welded only using inert gases su...

Страница 24: ...e wire feeding machine use the potentiometer to set the required speed of wire feeding on the wire feeding machine if necessary additional functions of welding process can be adjusted see changeover s...

Страница 25: ...on Once this happens stop moving the torch and weld the pothole which is a crater in the weld with fading out voltage Smoothness of this process can be controlled through voltage fade out time t dn wh...

Страница 26: ...will pulse in the range from 14 4 V A to 21 6 V with frequency of 20 Hz pulses will be of the same shape in terms of both magnitude and time If duty ratio parameter dut is changed to a value other tha...

Страница 27: ...ransfer to the mode of switching to the next welding mode this mode will be explained in the next paragraph 6 2 SWITCHING TO THE REQUIRED WELDING MODE If button 5 is pressed and held for more than 5 s...

Страница 28: ...ent 1 2 t HS Hot Start time 0 3 s by default a 0 1 1 0 s increment 0 1 s 3 Ar F Arc Force power 40 by default a 0 OFF 100 at low current values increment 1 4 u AF Arc Force trigger level 12 V by defau...

Страница 29: ...ent 1 7 Fr P current pulsing frequency 5 0 Hz by default a 0 2 50 0 Hz increment 0 1 Hz 8 dut mark to space ratio duty ratio is the ratio of larger current cycle to pulse spacing in percent 50 by defa...

Страница 30: ...s Set current value in MMA and TIG modes When working with wire of specified diameter in MIG MAG mode Minimum generator power 2 80 A at most 0 6 mm at most 2 9 kVA 3 120 A at most 0 8 mm at most 4 5 k...

Страница 31: ...g with an electrode TIG semiautomatic welding with wire MAG MIG 21 28 V 10 18 V 12 28 V 13 DELIVERY SET 1 Welding arc supply source with a mains cable 1 pce 2 Wire feeding machine rollers 0 6 0 8 and...

Страница 32: ...elding carefully follow these instructions Malfunctions that can reduce safety must be eliminated immediately USER S RESPONSIBILITIES The user assures that he will not allow working with the welding m...

Страница 33: ...ching the operating welding area welding cable must be robust intact and insulated Loose connections and damaged cables must be immediately replaced Mains cables and cables of the welding machine must...

Страница 34: ...PATON ProMIG series DC MMA TIG MIG MAG 32 Schematic electrical diagram of the Source PATON ProMIG 200 250 DC MMA TIG MIG MAG 220VAC...

Страница 35: ...G MIG MAG 16 ACCEPTANCE CERTIFICATE Arc inverter rectifier PATON PROMIG 200 250 Serial number ________________P has been approved for operation Sale date _____ _________________20____ Stamp here _____...

Страница 36: ..._____________________________________________________ __________________________________________________________________ Date of receipt for repair _____ _________________20____ __________________ sig...

Страница 37: ..._____________________________________________________ __________________________________________________________________ Date of receipt for repair _____ _________________20____ __________________ sig...

Отзывы: