Wireless Control Unit
84
12. Specifications
12. Specifications
12.1. Transmitter
Rated Voltage
12 to 24 VDC (24 VDC when LED unit or buzzer unit is installed)
Operating Voltage Range
10.8 to 26.4 VDC (21.6 to 26.4 VDC when LED unit or buzzer unit is installed)
Rated Current
Consumption
24V DC input
Main Unit
Maximum: 63 mA or less
LED Unit
Maximum: 42 mA or less (per tier)
Buzzer Unit
Maximum: 42 mA or less
12V DC input
Main Unit
Maximum: 53 mA or less
Operating Ambient Temperature
-10°C to +50°C
Operating Ambient Humidity
85% RH or less, no freezing, no condensation
Storage Ambient Temperature
-20°C to +60°C
Storage Ambient Humidity
85% RH or less, no freezing, no condensation
Mounting Location
Indoors
Mounting Direction
Upright
Protection Rating
IP 65 (IEC 60529), NEMA TYPE 4X,13
(IP54 when SZP-003W is mounted on the product body)
Environmental Conditions
Upright
Insulation Resistance
More than 5M Ω at 500 VDC between the live part and non-current carrying
metallic part
Withstand Voltage
500 VAC applied for 1 min between live part and non-current carrying
metallic part without breaking insulation
Mass (Tolerance: ±10%)
220 g *Hexagon nut with flange (Accessory) not included
External Dimensions
"4. Part Names and Dimensions" (
Interfaces
Terminal Block
Connector
Screwless Terminal Block (14 contacts)
Supported
Wire Diameter
Single wire:
φ
0.5 - 1.2 mm, Stranded wire: 0.2 - 1.5 mm
2
(AWG24-16)
Power supply
12 to 24 VDC input (12 to 24 VDC, GND)
Input
Number of Contacts
7 contacts
Output ON current
10 mA or less (per contact)
Input Reaction Time
100 ms or longer
Output
None
USB connector
USB 2.0 (Type-C connector)
*For maintenance purposes only, do not use.
Display Unit
Status Display Indicator