7. Operation
7.11.3. Wiring the Terminal Block Connector
• Lead wires are not included with this product. Please provide your own.
• Follow the steps below to wire the terminal block connector.
WARNING
Before any work is done, disconnect the power.
Be sure wiring is carried out correctly. Failure to follow these instructions could result in burning internal circuits or fire.
CAUTION
Do not use excessive force when pressing the lever of the terminal block connector.
To protect external equipment, install a fuse on the power supply side.
When wiring lead wires, consider the voltage drop along with the appropriate length and diameter.
Before turning on the power, check that the wiring and switch settings are correct.
Wire so that the core of the lead wire is not exposed. Failure to follow this instruction could cause a short circuit leading to
fire or equipment damage.
After completing the wiring, check for any loose wires. Failure to follow this instruction could result in malfunction or electric shock.
Lever
Terminal Block
Connector
Lead Wire
Insertion Slot
❷
❸
❶
Strip length 10 mm
●
Supported Wire Diameter
Single Wire
φ
0.5 - 1.2 mm (AWG24-16)
Stranded Wire
0.2 - 1.5 mm
2
(AWG24-16)
Point
●
Use a flat-blade screwdriver with a blade-edge width of 2.5 mm or less and thickness of 0.4 mm or less. (Or equivalent)
●
Do not push the screwdriver against the lever harder than necessary. Failure to follow this instruction could result in equipment damage.
●
Strip 10 mm of the insulation from the lead wire.
●
When removing the lead wire, do not simply pull the wire to remove it. (First press the lever down with a flat-blade screwdriver to release the lock.)
While placing a flat-blade screwdriver on the lever of
the terminal block connector, press down.
❶
Keep the lever pressed down and insert the stripped
lead wire into the lead wire insertion slot.
❷
With the lead wire inserted, release the flat blade
screwdriver from the lever. Check if the lead wire
is locked into place.
❸
ㅣ
When using a single wire or ferrule terminal, you can
connect by simply inserting the lead wire into the lead
wire insertion slot.