The product contains a hidden push button (Refer to       Part Names and Outer Appearance (P. 18))in the upper 
section, which can be operated as follows:
  - Alarm Sound Control …… Adjustable up to four steps.
  - LED Color Change ………  The luminescence color of each tier can be changed.
  - Version Confirmation …… The current version of the product can be checked.
  - Product Initialization ……… The memory contents of the product can be cleared and returned to factory default values.

(Returns to the Signal Tower setup mode. The alarm sound pattern and the "Smart Mode" setup data have not changed.)

Volume

 Large

Push Button

Push Button

Push Button

Push Button

Push Button

Volume

 Medium

Volume

Small

Mute

■Setup Button Operation Method (Alarm Sound Control)

If a problem occurs, check the following table to remedy the problem before calling for service.

Even after the above-mentioned symptoms were checked, but the problem is not solved, refer to the back of 
this book to fill out the "Product Specification Details for Inquiry" before contacting your nearest Patlite Sales 
Representative or our Technical Support.

Problem

Where to Check

Inspection Repair

Is the electric wiring connected correctly?

Is the power properly supplying the correct voltage?

Be sure to use 24VDC.

Is the setup data correct?

Check that the contents of the setup data is correct.

Is the setup data correct?

Check that the contents of the setup data is correct.

Is the setup data correct?

Check that the contents of the setup data is correct.

Is the setup data correct?

Check that the contents of the setup data is correct.

The LED does not 
light up.

Is the electric wiring connected correctly?

Is the power properly supplying the correct voltage?

Be sure to use 24VDC.

Check that the product type has a alarm 
included or not.

The alarm does not 
sound.

The alarm volume is 
too low.

Is the electric wiring connected correctly?

Check that the product type has a alarm 
included or not.

The LED does not 
flash.

Only products with         added to the part 
number include the alarm function.

B

Priority is given to the lighting input over the flashing
input when simultaneous signals are applied.

Is the electric wiring connected correctly?

A different LED tier 
from what I thought 
lights up when I 
make it turn on.

No.

Is the alarm volume set to minimum?

Refer to        Setup Button Method  (->P.25) 
on how to adjust the volume.

Are the external contacts for lighting turning on?

<Product Specification

 details for Inquiry>

Product Name

Model

Signal Tower

(→         Model Number Configuration" (P. 17))

Purchase Date

Symptoms of Problem

Year/Month/Day

With as much detail as possible.

2

1

2

3

4

5

To find out more about operation methods other than "Alarm Sound Control", 
visit our company's homepage (http://www.patlite.com) for further details.

25

Standard

Mode

Only products with         added to the part 
number include the alarm function.

B

How to use the "Setup Button"

7

3

Troubleshooting

8

Refer to        Wiring  (->P.22, 23). to verify 
wiring is correct.

5

7

Refer to        Wiring  (->P.22, 23). to verify 
wiring is correct.

5

Refer to        Wiring  (->P.22, 23). to verify 
wiring is correct.

5

Refer to        Wiring  (->P.22, 23). to verify 
wiring is correct.

5

26

Specifications

9

Specifications

No.1

No.2

No.3

No.4

No.5

No.6

No.7

No.8

No.9

No.10

No.11

LA6-3DLJ□N

930g

LA6-5DLJ□N

1040g

LA6-3DLJ□B

980g

LA6-5DLJ□B

1090g

LA6-3DWJ□N

400g

LA6-5DWJ□N

510g

LA6-5DTN□N

530g

LA6-3DWJ□B

450g

LA6-5DWJ□B

560g

3600Hz, Continuous beep sound

2400Hz&3375Hz, 0.25sec/0.25sec

Mass

(±10%)

LA6-3DTN□B

480g

LA6-5DTN□B

590g

LA6-3DTN□N

420g

Standby Current

Max. 15mA

   500VAC applied for 1 min between terminals and chassis without breaking insulation

4000Hz&4800Hz, 0.5sec/0.5sec

Alarm Sound

2400Hz, Continuous beep sound

Alarm Sound No.1 measured from the front direction of the alarm opening at 1m

Sound Level

Max. 85dB

Model

Flashing Rate

   60±2  Flashes Per Minute

Signal Wire Current

Display Color

(Typical Luminous Intensity)

Red(1000mcd) Amber(1700mcd) Green(2600mcd) Blue(1000mcd) White(1250mcd)

Purple(800mcd) Pink(850mcd) Lemon Yellow(2150mcd) Cyan(2150mcd)

RoHS Directive (EN 50581)

2400Hz&3600Hz, 0.25sec/0.25sec

Data Programming

Application Software

Exclusive Application Software

Environmental Condition

Volume Control

4 steps in volume selection from Setup Pushbutton (Factory Default: Max.)

   Max.   -           5dB of Max. (APPROX.)                 -10dB of Max. (APPROX.)                  OFF

Remarks

CE Marking Compliant

UL Recognized Component (File No.E215660), Maximum Surrounding Temperature Rating 60℃

More than 1MΩ at 500VDC between the terminals and the chassis

Insulation Resistance

Protection Rating

Environmental Condition

Vibration Resistance

LA6-□□TN□□

Spot:Acceleration 10m/s

2

(57.5〜150Hz)

IP65(Alarm specification:  IP54)  IEC 60529

Upright Installation

Indoor Only

JIS C 60068-2-6:2010

LA6-□□LJ□□

Sweep:Amplitude 0.30mm p-p(10〜57.5Hz), Acceleration 20m/s

2

(57.5〜150Hz)

Spot:Acceleration 20m/s

2

(57.5〜150Hz)

LA6-□□WJ□□

Sweep:Amplitude 0.30mm p-p(10〜57.5Hz), Acceleration 20m/s

2

(57.5〜150Hz)

Less than 90% (No Dew or Condensation)

Upright

Storage Ambient Humidity

Horizontal

Inverted

Mounting Location

Mounting Direction

Less than 90% (No Dew or Condensation)

- 25℃ 〜 +  60℃

Operating Ambient Humidity
Storage Ambient Temperature

Operating Ambient Temperature

- 25℃ 〜 +  60℃

Rated Voltage

Max. 70mA

24V DC

Operating Voltage Range

±10% of  Rated Voltage

LA6-3D□□N-YYY

4.5W

Typ.

Environmental Condition

Rated Power
Consumption

LA6-5D□□B-YYYYY

8W

LA6-□D□□□-□ (Refer to "2. Model Number Configuration")

Alarm Sound No.1 at Maximum Volume

LA6-3D□□B-YYY

5.5W

Max.

LA6-5D□□N-YYYYY

7W

LA6-5D□□B-RYGBC

6.5W

LA6-3D□□B-RYG

4.5W

LA6-5D□□N-RYGBC

5W

LA6-3D□□N-RYG

3.5W

Environmental Condition

Upright Installation

Main Unit

USB micro-B Female

Interface:USB2.0/1.1, Transmission speed:USB2.0/1.1/1.0

Transfer

cable

Micro USB cable (Not included), Data transfer/Chage cable

Connector type:USB Male (Type.A) - USB Male (Type.MicroB)

Operating Mode

Signal Tower Mode / Smart Mode

Withstand Voltage

Conformity Standards

UL508, CSA-C22.2 No. 14

EMC Directive (EN 61000-6-4, EN 61000-6-2)

FCC Part15 SubpartB Class A

KC (KN 61000-6-4, KN 61000-6-2)

3600Hz, Intermittent at 0.05sec

2400Hz, Intermittent at 0.05sec

2400Hz, Intermittent at 1.5 sec

2400Hz, Intermittent at 0.5sec

3600Hz, Intermittent at 1.5 sec

3600Hz, Intermittent at 0.5sec

Data Transmission 
Interface

(Typical Frequency)

(Downloadable from Home Page)

ghv Vertriebs-GmbH

 | Am Schammacher Feld 47 | 85567 Grafing | T 49 80 92 81 89 0 | [email protected] |

 www.ghv.de

Содержание LA6 series

Страница 1: ...be performed by a professional contractor if construction work is involved Prior to installation read this manual thoroughly before using this product to ensure correct use To nd out more about operat...

Страница 2: ...rring use this product together with other equipment To ensure safety when this product is installed onto equipment observe the following Avoid long exposure to the alarm sound from a close distance F...

Страница 3: ...ound direction For Flashing Alarm Speci cations B By all means do not apply voltage to the Flashing Pulse Enable Common line Failure to comply may result in malfunction Flashing Alarm Specifications D...

Страница 4: ...5 3 B N B B N N 5 3 5 3 Spec Overallheight 330 264 290 224 B B N N 5 3 5 3 WJ TN WJ TN TN The full product appearance is indicated according to its model number Refer to the model numbers as a refere...

Страница 5: ...he USB cover is closed at all times If not securely closed its waterproof performance will decrease 60 Wire length 1060 40 70 284 294 313 5 16 10 1 3 4 6 7 10 12 2 5 Steel pole with mounting angle and...

Страница 6: ...Install the signal tower on a sturdy surface Install the signal tower on a level surface Only install the signal tower in an upright or inverted position This equipment has been tested and found to c...

Страница 7: ...se sealing to prevent water intrusion from the mounting back side If the installed environment exposes water etc to the back side of the mounting surface be sure to Use sealing on the mounting and dis...

Страница 8: ...e Gauge Solid Wire AWG20 16 Wire Gauge Frayed Wire 1 Red 2 Orange 3 Green 4 Blue 5 White 6 Gray 7 Black 8 Yellow 9 Gray 10 Black 11 Note Theleadwirecolordoesnot indicatetheLEDluminescencecolor Caution...

Страница 9: ...ignal Tower mode with a PLC it is necessary to separate the ashing and non ashing circuit outputs on the PLC side Without flashing alarm B N With flashing alarm Do Not Apply Voltage Screwless Terminal...

Страница 10: ...8 1 Micro USB Cable USB A Male to USB Micro B Male Note The micro USB cable should be able to charge batteries and transmit data The MicroUSB cable is not included with this product Micro USB Connecto...

Страница 11: ...etup data correct Check that the contents of the setup data is correct The LED does not light up Is the electric wiring connected correctly Is the power properly supplying the correct voltage Be sure...

Страница 12: ...IP54 IEC 60529 Upright Installation Indoor Only JIS C 60068 2 6 2010 LA6 LJ Sweep Amplitude 0 30mm p p 10 57 5Hz Acceleration 20m s2 57 5 150Hz Spot Acceleration 20m s2 57 5 150Hz LA6 WJ Sweep Amplit...

Страница 13: ...s Waterproof Ring B x 2 The Direct mount Bracket is a single article Direct mount Bracket The Terminal Block Bracket is a single article Terminal Block Bracket Set of Pole Bracket Pole Waterproof Ring...

Страница 14: ...28 ghv Vertriebs GmbH Am Schammacher Feld 47 85567 Grafing Telefon 49 80 92 81 89...

Страница 15: ...type only 10 10 type LJ For type TN Name Plate Location CAUTION If using a copier machine Ensure that it is actual size Scale for dimensions check 0 10 20 30 40 50 Wire Exit Hole 12 type WJ Wire Exit...

Страница 16: ...Memo Installation template Do not write here ghv Vertriebs GmbH Am Schammacher Feld 47 85567 Grafing Telefon 49 80 92 81 89...

Отзывы: