Patlite LA6 series Скачать руководство пользователя страница 1

15

16

17

18

20

24

25

25

26

27

22

Page

Signal Tower

1

2

3

4

5

6

7

8

9

10

Safety Precautions

Model Number
Configuration

Part Names and
Outer Appearance

How to Install

Wiring

Setup Data Transmission
Method

How to use
the "Setup Button"

Specifications

Replacement Parts

Troubleshooting

TYPE

L A 6

INSTRUCTION MANUAL

[ Maintenance Version ]

Installation

Operation

Maintenance

Thank you very much for purchasing our PATLITE product.
●Request the installation and wiring be performed by a 

professional contractor if construction work is 
involved.

●Prior to installation, read this manual thoroughly 

before using this product to ensure correct use.

●To find out more about operation method, visit our 

companyʼs homepage (http://www.patlite.com) for 
further details.

●After reviewing this manual, if there are any questions 

regarding this product, please contact the nearest 
PATLITE office listed on the back cover of this manual.

Notice to Customer

●Read this manual carefully prior to  installation.
●Be sure to return this manual to the customer.

Notice to Contractor

OK !

Head Cover

USB cover

Warning

Failure to observe the following may result in death or serious injury.

To prevent from 

short-circuits or 

damage

, observe the following:

Request the installation and 
wiring be performed by 

professional contractor

 if 

construction work is involved.
Failure to comply may result in 

fire, electric shock or falling

 from 

high places may occur.

To ensure proper safety while 
using the signal tower, observe 
the following:

To ensure safety when this 
product is installed onto 
equipment, observe the following.

Be sure to discharge any static 
electricity from the body before 
handling static sensitive parts of 
this product.
(To prevent damage from static 
electricity, touch hands or other 
body parts to metals or an earth 
ground to discharge the body 
from static charge.)

- Be sure the signal tower is 

disconnected from the power 
supply before wiring or 
performing repair work.

- Use the signal tower in 

properly maintained condition

(If parts such as the base or 
outer cover lens are cracked, 
they should be repaired.)

- Perform periodic pre-maintenance.
- As a precaution against problems 

occurring, use this product 
together with other equipment.

To ensure safety when this product 
is installed onto equipment, 
observe the following.

Avoid long exposure to the alarm 
sound from a close distance. Failure 
to observe this may lead from 
irritation to permanent damage to 
the ears.
(        Flashing/Alarm Specifications)

- Do not Use the signal tower as 

leverage when climbing up onto 
the equipment. Failure to 
comply will result in 

falling from 

a high place, or damage to the 
product.

- When performing tasks such as 

opening the covers of the 
equipment, be careful not to 
snag anything on the signal 
tower. Failure to comply will 
result in 

product damage.

Caution

Failure to comply with the following points may result in injury, 
physical loss or damage.

To maintain the dust and 
waterproof performance for this 
product, observe the following:

- Keep the head cover attached at 

all times.

- Ensure the USB cover is closed at 

all times.

- Do not remove parts beyond 

those designed to be removed 
from this product.

 (Refer to        Part Names and 

Outer Appearance (P. 18) for 
parts which can be removed)

- Do not modify or disassemble 

this product.

- Use only the specified 

replacement parts listed in this 
manual.

B

Notice

16

Safety Precautions

Safety Precautions

1

3

ghv Vertriebs-GmbH

 | Am Schammacher Feld 47 | 85567 Grafing | T 49 80 92 81 89 0 | [email protected] |

 www.ghv.de

Содержание LA6 series

Страница 1: ...be performed by a professional contractor if construction work is involved Prior to installation read this manual thoroughly before using this product to ensure correct use To nd out more about operat...

Страница 2: ...rring use this product together with other equipment To ensure safety when this product is installed onto equipment observe the following Avoid long exposure to the alarm sound from a close distance F...

Страница 3: ...ound direction For Flashing Alarm Speci cations B By all means do not apply voltage to the Flashing Pulse Enable Common line Failure to comply may result in malfunction Flashing Alarm Specifications D...

Страница 4: ...5 3 B N B B N N 5 3 5 3 Spec Overallheight 330 264 290 224 B B N N 5 3 5 3 WJ TN WJ TN TN The full product appearance is indicated according to its model number Refer to the model numbers as a refere...

Страница 5: ...he USB cover is closed at all times If not securely closed its waterproof performance will decrease 60 Wire length 1060 40 70 284 294 313 5 16 10 1 3 4 6 7 10 12 2 5 Steel pole with mounting angle and...

Страница 6: ...Install the signal tower on a sturdy surface Install the signal tower on a level surface Only install the signal tower in an upright or inverted position This equipment has been tested and found to c...

Страница 7: ...se sealing to prevent water intrusion from the mounting back side If the installed environment exposes water etc to the back side of the mounting surface be sure to Use sealing on the mounting and dis...

Страница 8: ...e Gauge Solid Wire AWG20 16 Wire Gauge Frayed Wire 1 Red 2 Orange 3 Green 4 Blue 5 White 6 Gray 7 Black 8 Yellow 9 Gray 10 Black 11 Note Theleadwirecolordoesnot indicatetheLEDluminescencecolor Caution...

Страница 9: ...ignal Tower mode with a PLC it is necessary to separate the ashing and non ashing circuit outputs on the PLC side Without flashing alarm B N With flashing alarm Do Not Apply Voltage Screwless Terminal...

Страница 10: ...8 1 Micro USB Cable USB A Male to USB Micro B Male Note The micro USB cable should be able to charge batteries and transmit data The MicroUSB cable is not included with this product Micro USB Connecto...

Страница 11: ...etup data correct Check that the contents of the setup data is correct The LED does not light up Is the electric wiring connected correctly Is the power properly supplying the correct voltage Be sure...

Страница 12: ...IP54 IEC 60529 Upright Installation Indoor Only JIS C 60068 2 6 2010 LA6 LJ Sweep Amplitude 0 30mm p p 10 57 5Hz Acceleration 20m s2 57 5 150Hz Spot Acceleration 20m s2 57 5 150Hz LA6 WJ Sweep Amplit...

Страница 13: ...s Waterproof Ring B x 2 The Direct mount Bracket is a single article Direct mount Bracket The Terminal Block Bracket is a single article Terminal Block Bracket Set of Pole Bracket Pole Waterproof Ring...

Страница 14: ...28 ghv Vertriebs GmbH Am Schammacher Feld 47 85567 Grafing Telefon 49 80 92 81 89...

Страница 15: ...type only 10 10 type LJ For type TN Name Plate Location CAUTION If using a copier machine Ensure that it is actual size Scale for dimensions check 0 10 20 30 40 50 Wire Exit Hole 12 type WJ Wire Exit...

Страница 16: ...Memo Installation template Do not write here ghv Vertriebs GmbH Am Schammacher Feld 47 85567 Grafing Telefon 49 80 92 81 89...

Отзывы: