CONVERTING TO A DIFFERENT GAS TYPE (MATCH LIT)
To convert
MATCH LIT MANUAL UNITS (only)
from propane to natural gas or from natural to propane gas,
carefully follow the steps below:
1. SHUT OFF THE GAS SUPPLY TO THE UNIT AND ANY NEARBY ELECTRICAL SOURCES OR
APPLIANCES
.
2.
If present, remove all decorative media from the unit.
3.
Remove the screws attaching the burner pan to your enclosure.
4.
Carefully detach the ex connector attached to the ori ce holder (see
Fig. 3
) and unscrew the ori ce
holder from the burner pipe (see
Fig. 4
).
5.
Remove the ori ce from the holder (see
Fig. 4
) and replace with the proper-sized one for your gas
requirement. Propane gas requires a 2.30mm(drill size) orifice.Natural gas require a 3.78mm orifice.
Note:
If you are converting
to and using natural
gas you
MUST
install the air shutter over burner pipe to
cover the air holes (see
Fig. 4
). For
propane
(L.P.) gas, remove the air shutter.
Replace the ori ce holder and reattach the connector from the valve (see Fig. 3).
The regulator must now be converted to the new gas type.
6.
To convert the regulator from propane gas to natural gas.
The appliance must be isolated from the gas supply piping system by closing , It's individual manual
shout off valva suring any pressure testing of the gas supply piping system. At test pressure equal to
or less than 1/2 psi (3.5 Kpa).
7.
Move the propane pipe from regulator (see Fig. 5) and replace with 3/8" natural gas pipe
(natural gas pipe package not included).
8.
Restore your gas supply and check for leaks per the INSTALLATION section. When no leaks are
detected, fasten the burner pan back into place on the enclosure and replace the decorative media.
Note: You should paste sticker lab on fire pit after changing NG system !
!
Fig. 4
Burner
pipe
ORIFICE
(Remove to change to a different
gas type)
2.30mm-propane gas
3.78mm-natural gas
Air shutter
(Used only with
natural gas. Removed for
propane gas.)
Connector from valve attached to
orifice holder on burner pipe
Fig. 1
Detach connector from orifice holder when
changing orifice to a different gas type.
Fig. 3
Install gas pipe.
Fig. 2
Remove propane pipe.
NG Orifice & Air Shutter
NO. OA01