•  100-240VAC 50/60Hz wide-range power input

•  0.08A maximum power consumption

• 

3000V opto-isolation between DMX data links

•  250V fault protection on DMX ports

• 

Star wiring is permitted only in conjunction with a repeater

• 

All cabling must be a continuous daisy-chain. No “tees” are 

permitted

• 

Cable shield is earth-grounded at one end only, preferably at the 

control console

• 

Maximum length of one cable segment is 1,800 ft. (550m)

• 

The last DMX device on the line must be terminated with a 100 

or 120Ω resistor between pins 2 and 3

• 

Cable must be Belden 9842 (120Ω), 9829, 9729 (100Ω), ISO/

IEC 11801 (Cat5) or equivalent

• 

Keep all DMX cabling away from high voltage or power cables 

to maintain data integrity

When equipped with 5-pin XLR connectors, this product complies 

with the current ANSI E1.11 DMX512-A standard and all previous 

standards to DMX512 (1990).
Screw terminal connector and RJ45-equipped models are compliant  

with E1.11 DMX512-A under the non-compatible connector (NCC) 

provision. RJ45-equipped models are intended for installation in 

restricted-access equipment rooms and should not be used as 

portable gear. Accidental connection to data switching or other 

equipment may cause damage to equipment and/or personal injury.
All DMX ports are protected to 250V with self-healing circuitry.

PWREP RM P8 NONRDMs are intended for desktop use, or may 

be mounted in a standard 19” equipment rack, using the rack ear 

kit included.

Truss-mount adaptors (PWACC TMLG) and wall-mount adaptors 

(PWACC WMLG) are also available.

The PWREP RM P8 NONRDM is intended for installation in a dry, 

indoor location. Operating conditions: 

14°F-122°F (-10°C to 50°C); 

5-95% relative humidity, non-condensing.

Warning:

 The AC socket outlet shall be installed near the 

equipment and shall be easily accessible.

Warning:

 This equipment relies upon building installation primary 

overcurrent protection.

Warning:

 Except for the IEC chassis plug marked for AC input, 

all ports on the PWREP RM P8 NONRDM are intended for 

low voltage data lines only. Attaching anything other than low 

voltage sources to the data ports may result in severe equipment 

damage, personal injury or death.

DMX BASICS

DMX512-A COMPLIANCE

INSTALLATION

• 

ANSI E1.11 DMX512-A R2013

•  UL

• 

RoHS 2011/65/EU + A1 2015/863

•  CE

COMPLIANCE

•  5.2 lbs (2.4 kg)

• 

17”W x 1.7”H x 7”D (432mm x 43mm x 178mm)

•  Operating Conditions: 14°F-122°F (-10°C to 50°C); 5-95% 

relative humidity, non-condensing

PHYISCAL

ELECTRICAL INFORMATION