MODEL 7748 SINGLE CHANNEL RS530 DB25 A/B SWITCH W/CUTOFF, TELNET AND GUI
Electro Standards Laboratories, Inc.
(401) 943-1164
www.electrostandards.com - pg 13 - Pub. 4703-02
automatically. Therefore it is important that you consult your network
administrator for a correct static IP address in order to greatly reduce
the chance of conflicts.
Resetting the Remote Ethernet Port
The Remote Ethernet port can be reset to factory defaults. This is
especially useful in the event that an invalid IP address configuration is
set and the unit becomes inaccessible through the Remote Ethernet
port. To reset the IP address settings and any security settings (such
as password protection on the Telnet Configuration port), the following
steps must be performed:
•
Power down the unit.
•
While holding any front panel pushbutton, power the unit back
up. The pushbutton can be released once any of the LED’s on
the front panel light up steadily.
•
The unit will run through its reset routine. While this is
occurring, all LED’s will flash sporadically until it has finished.
The entire process can take about up to 7 seconds.
Once the reset routine is complete, the unit will be ready for operation
without any further power cycling. It may be a few additional moments
before the Remote Ethernet port is accessible while the unit acquires an
IP address.