Pathway connectivity solutions Pathport 6423 Скачать руководство пользователя страница 3

Installation Guide

PATHPORT INSTALL GUIDE-REV7

12/10/18

empty of debris. Inspect the Uno and make sure all components 

are securely fastened and that the printed circuit boards are intact.

If the back backbox contains an Ethernet  RJ45 female punchdown-

connector, use a male-to-male jumper to connect it to the Uno.

 

Otherwise, plug the male RJ45 pigtail directly into the connector 

on the back of the Uno. Attach the green ground wire to the ground 

screw in the backbox.

Gently insert the Uno straight into the backbox and screw it into 

place with the long mounting screws provided. Place the cover plate 

over the installed Uno and use the two short screws to fasten the 

cover plate. Do not over-tighten these screws.

Disconnect all power before proceeding.

Because Pathport eDINs are intended for installation within 

enclosures, if you are installing multiple gateways it’s a good idea to 

maintain a log of serial numbers. The serial numbers are exposed 

when the gateways are discovered in Pathscape which is where they 

will be patched. If the devices are easily visible from where you run 

Pathscape, use the “Identify” feature, which will blink the blue Identify 

LED on the selected gateway.
Securely mount DIN rail (if not already installed in the enclosure). 

Hook the upper slots on the back of the plastic extrusion to the DIN 

rail and then gently but firmly press on the bottom front corners of 

the extrusion to snap the module onto the rail. Do NOT press directly 

on the PCB card itself.
Attach the DMX wiring to the terminal strip output connector(s). If 

the Pathport eDIN is using an auxiliary power supply, connect the 

terminal strip. Observe DC polarity.
Attach the network cable to the RJ45 connector marked Ethernet. 

The Pathport is ready to be powered up. Both auxiliary power and 

PoE can be connected simultaneously without damaging the Path-

port eDIN.
Pathport 1011’s may be set permanently to a specific DMX universe, 

1 through 4, by use of a DIP switch block on the circuit board. If the 

system designer has not given specific instructions about this setting, 

all switches should be left in the OFF position, and configured with 

Pathscape.

The  Portable  Uno  may  be  powered 

 

using Power-over-Ethernet or a 24VDC 

supply  with  a  2.5mm  center-positive 

barrel connector.
To  attached  the  hanging  bracket 

 

(included),  remove  the  top  two 

screws from either end of the 

portable enclosure (four screws 

 

altogether),  position  the  hang

-

ing bracket over the top of the 

 

enclosure, then use the same screws 

to attach the bracket to the enclosure.

The  hanging  bracket  has  a  1/2”  (12.5mm)  hole  suitable  for  a 

C-Clamp or other hanger (not included).

The  Pathport  Touring  Edition  operates  on  Power-over-Ethernet 

during normal operation, but may be configured using power from 

a 9V battery (included).
Once connected to a PoE source, the Pathport Touring Edition is 

ready for use.
It may be configured using its front panel or with Pathscape over 

the network.

The Pathport QUATTRO operates on Power-over-Ethernet or an 

auxiliary 24 or 48 VDC supply with a 2.5mm center-positive barrel 

connector (supply not included).
Once powered up, the Pathport QUATTRO is ready for use. There 

is no on/off switch.
The Pathport QUATTRO is designed for installation in a standard EIA 

19” rack, with the LCD and encoder facing out. Attach the rack ears 

(included) to either side of the enclosure using the Phillips screws 

provided (two per ear). Attach the Pathport QUATTRO to the rack 

using standard rack screws (not included).
A joiner is included to allow two QUATTROs to be installed side-by-

side in 1RU of rack space. Wall (P/N #9005) and truss mount (P/N 

#9004) adapters are available as accessories.

PATHPORT eDIN (1011, 1012, 6824)

PATHPORT PORTABLE UNO (6151, 6152)

PATHPORT TOURING EDITION (6182)

PATHPORT QUATTRO (6321, 6322, 6326)

Отзывы: