3
1 - SAFETY INFORMATION
WARNING
Do not install this system in mobile home! Boiler is
not approved for installation in mobile home. Doing
so could cause fi re, personal injury or loss of life.
Instructions intended as aid to qualifi ed, service
personnel for proper installation, adjustment and
operation of this system. Read instructions before
attempting installation or operation. Failure to follow
instructions could cause malfunction of system and
result in death, serious bodily injury. Consult qualifi ed
installer, service agency or gas supplier for assistance
or additional information.
!
1.1 Safety Information
Check all applicable state, local building codes and
•
utility company requirements before installation.
Installation shall conform to these requirements in
their entirety. In absence of these codes, use NFPA,
National Gas and National Electric installation codes
and authority having jurisdiction.
Use only with gas approved for system components.
•
Refer to boiler and MCHP unit rating plates.
Provide adequate combustion and ventilation air to
•
system space as specifi ed in Section 10, “Combustion
Air and Vent Pipe.”
Combustion products shall be discharged outdoors.
•
Connect system components (boiler and MCHP unit)
to approved vent system only, specifi ed in Section 10,
“Combustion Air and Vent Pipe’.
Allow system to cool before servicing.
•
Shut off electricity and gas supply connected to system
•
before servicing.
Never test for gas leaks with open fl ame. Use
•
commercially available soap solution specifi cally made
for detection of leaks to check all connections. See
Section 11, ‘Gas Supply Piping’.
Verify natural gas input rate is correct. Over fi ring
•
may result in early failure of the boiler’s components.
Under fi ring may result in too much air for combustion
process causing poor or loss of combustion.
Install boiler to operate within its intended temperature
•
range. See boiler ‘Installation Operation & Maintenance’
manual.
Follow regular service and maintenance schedule for
•
effi cient and safe operation.
Keep system area clean of debris and free from
•
combustible and fl ammable materials.
System is not intended for temporary heating of
•
buildings under construction.
System is not do-it-yourself project. Install and servic
•
e
by qualifi ed professionals only.
WARNING
Fire, explosion, asphyxiation and electrical shock
hazard. Improper installation could result in death
or serious injury. Read this manual and understand
all requirements before beginning installation.
!
WARNING
Do not store or use gasoline or other fl ammable
vapors and liquids, or other combustible materials in
vicinity of this or any other appliance.
Natural gas and propane are normally odorized
by fuel supplier. Odorant may not be perceivable.
Installation of UL and CUL recognized fuel gas
detectors installed in accordance with manufacturer’s
instructions is recommended as additional safety.
Exhaust gases from boiler contain chemicals which
may include carbon monoxide (CO). Carbon
monoxide is odorless, tasteless, clear colorless
gas, which is highly toxic. Even low concentrations
are suspected of causing birth defects and other
reproductive harm.
!
NOTICE
Installation Requirements Specifi c To The State Of
Massachusetts, boiler installation must conform to
Commonwealth of Massachusetts code 248 CMR
which includes but is not limited to: Installation by
licensed plumber or gas fi tter.
NOTICE
UL and ULC recognized CO detectors are required
for all buildings equipped with ECR freewatt PLUS
System. All CO detectors should be installed in
accordance with manufacturer’s instructions and
applicable local building codes.
Содержание freewatt HDJ
Страница 11: ...11 Figure 2 8 MCHP Electrical Connection Details 2 INTRODUCTION Figure 2 9 MCHP Front Interface Details...
Страница 43: ...43 15 DETAILED SEQUENCE OF OPERATION...
Страница 44: ...44 15 DETAILED SEQUENCE OF OPERATION...
Страница 57: ...57 17 5 HDJ 240 VAC Wiring Only 17 PIPING AND WIRING SCHEMATICS...
Страница 58: ...58 17 6 HDJ 120 VAC Wiring Only 17 PIPING AND WIRING SCHEMATICS...
Страница 59: ...59 17 7 HDJ 120 VAC Wiring Control Module Zone Pumps 17 PIPING AND WIRING SCHEMATICS...
Страница 60: ...60 17 8 HDJ 120 VAC Wiring Control Module Zone Valves 17 PIPING AND WIRING SCHEMATICS...
Страница 61: ...61 17 9 HDJ 120 VAC Wiring Control Module Hydro Air 17 PIPING AND WIRING SCHEMATICS...
Страница 62: ...62 17 10 HDJ Low Voltage Wiring Only 17 PIPING AND WIRING SCHEMATICS...
Страница 63: ...63 17 11 HDJ Low Voltage Only Wiring Control Module and Zone Pumps 17 PIPING AND WIRING SCHEMATICS...
Страница 64: ...64 17 12 HDJ Low Voltage Only Wiring Control Module Zone Valves 17 PIPING AND WIRING SCHEMATICS...
Страница 66: ...66 17 PIPING AND WIRING SCHEMATICS 17 13 HDJ Low Voltage Only Wiring Control Module Hydro Air...
Страница 67: ...67 17 PIPING AND WIRING SCHEMATICS 17 14 MCHP Low Voltage Wiring...