CALIBRATION:
Set Symmetry pot in the middle, Coarse, Fine Tune pots to minimum.
Connect the CV out from your sequencer to V/OCT input, send
the SINE out to your DAW.
In your DAW open tuner VST to monitore notes.
Send C1 from your sequencer, in your DAW monitor the output while
turning the multiturn trimmer to read C1
.
Send C9 from your sequencer, monitor your DAW to read C9
while turning the multiturn trimmer to read C9
.
Send C1 again from your sequencer, monitor your DAW to read
C1 while truning the multiturn trimmer marked C1.
Repeat the proccess as much as needed until you finish to adjust.
0
Tuner
Reference
440Hz
-50
+50
32.7Hz
C
DAW
0
Tuner
Reference
440Hz
-50
+50
8192Hz
C
DAW
Содержание OPERAT
Страница 1: ...OPERAT USER MANUAL ...