EI65 TROUBLESHOOTING HANDBOOK
031-300-190-035 REVISION A 01/25/99
4
3.1 NO DISPLAY
PROBLEM: Blank console display with no warning light shown.
Measure crane voltage on connection board between X1:1 (+UB) and X1:3 (ground).
Refer to Drawing 1, System Diagram, Section 5. Drawings.
Check fuse F1 in console.
Refer to Drawing 2, Connection Board, Section 5. Drawings.
Correct?
Replace fuse (2amp/250V)
Measure voltage on connection board between MP4 (+5.25V) and MP1 (ground).
Refer to Drawing 2, Connection Board, Section 5. Drawings.
Correct?
Defect on connection board. Replace
console connection board.
Replace console main board.
Correct?
Start
No
Check crane power supply for faulty
crane electric or if supply is too low.
No
No
Measure voltage to main board between MP15 (+5.25V) and MP1 (ground).
Refer to Drawing 3, Main Board, Section 5. Drawings..
Yes
Yes
Yes
Содержание EI65
Страница 4: ......
Страница 16: ...EI65 TROUBLESHOOTING HANDBOOK 031 300 190 035 REVISION A 01 25 99 12...
Страница 20: ...EI65 TROUBLESHOOTING HANDBOOK 031 300 190 035 REVISION A 01 25 99 16 5 DRAWING 7 ANGLE SENSOR CIRCUIT...
Страница 21: ...EI65 TROUBLESHOOTING HANDBOOK 031 300 190 035 REVISION A 01 25 99 17 5 DRAWING 8 LINERIDER CIRCUIT...