Data Logger Operator's Manual
iFLEX5
© PAT Rev. - 10/17/03
190175_-
2
3 USER GUIDE
3.1
READING OUT A MEMORY CARD DIRECT WITH PC
(DOS-DRIVE CAN)
Step
no.
Action
1
Switch off iflex5
2
Take memory card out of the DOS-DRIVE CAN slot
3
Copy the data logger file from the memory card to the hard disk of the PC
4
put memory card into the DOS-DRIVE CAN slot
3.2 DATA
EVALUATION
The PC program GBASE or AUSWERT is used for data evaluation. The data transfer is carried
out direct on the PC with PC CARD drive.
3.3
DATA LOGGER INITIALIZATION
Step
no.
Action
1 Parameterization
LMI
2
Connect DOS-DRIVE CAN with the iflex5
3
Switch on the LMI
Terminal display:
LMBP02: F= Datalogger
LMBP02: Init CAN Datalogger
(DOS-Drive CAN)
6
Press the button “F”
Terminal display:
USER NO:
7
Input the user number 17848, then press the button “ENTER”
Terminal display:
<< Datalogger System Setup >>
< T > Setup Time base
< L > Initialize Memory card
< C > Counter Calibration
8
Press the button “T”, then setup date and time
After every change the system resets to. Only after a reset the system clock is
changed.
9
Press the button “C”, then setup the utilization counters.
The utilization counters are deactivated, if the maximum count, option “<2> Counter
Limit” of the respective counter is set to “0”
10
Press the button “L”
Terminal display:
Crane No: <crane number>
11
Input of the crane number, or enter old crane number. Press the button “ENTER”
Terminal display:
Crane number: 12345678