Pass XS PHONO Скачать руководство пользователя страница 10

10

11

Pass Laboratories, 13395 New Airport Rd., Suite G., Auburn,

95602

CA

Phone: 530.878.5350, Fax: 530.878.5358, Web: www.passlabs.com

Warranty:

Please check with the factory authorized distributor in the country where you are purchasing
this product for speci

fi

c warranty information.

All Pass Laboratories products purchased new from an authorized Pass Laboratories dealer in
North America are covered by a transferable, limited 3-year warranty. This warranty includes
all parts and labor charges incurred at the factory or factory speci

fi

ed repair facility, exclusive

of any subsequent or consequential damages. Damage due to physical abuse is speci

fi

cally

excluded under this warranty.

For this warranty to apply the customer is responsible for returning the product unmodi

fi

ed to

the factory within the speci

fi

ed warranty period. The customer assumes all responsibility for

shipping and insurance to and from the factory or a factory speci

fi

ed repair facility. The

conditions and stipulations of this Pass Laboratories warranty only applies to units originally
sold new through an authorized dealer. Warranty on factory repair is 60 days and covers only
the scope of the original repair.

Non-North America customers should consult with their original Pass Labs dealer or
distributor for warranty repair instruction prior to contacting the factory or shipping product
to the factory for repair.

Non-North American product must be returned to the country of origin for warranty service.
Foreign distributors are only required to offer warranty service on Pass Laboratories product
that they have imported, veri

fi

able by serial number.

Please note: Conditions of warranty service and customer rights for product purchased
outside the United States may vary depending upon the distributor and local laws. Please check
with your local distributor for speci

fi

c rights and details.

Any modi

fi

cations to Pass Laboratories products that have not received written factory

approval nullify all claims and void all provisions of the warranty and liability by the maker or
authorized distributor. Should a modi

fi

ed product be returned to the factory for repair the

owner will be required to pay all necessary charges for the repair in addition to those charges
required to return the product to it's original con

fi

guration.

In the case of safety issues, no product shall be returned to the customer without those safety
issues being corrected to the most recent accepted standards.

Removal or alteration of original Pass Labs serial numbers voids the factory warranty. Product
with altered or missing serial numbers will be suspect as counterfeit or stolen product.

Pass Laboratories will not repair or in any way indemnify any counterfeit or cloned product.

Pass Laboratories does not offer products in voltages intended for international markets
either to authorized Pass Labs dealers or to third parties located in the United States or
Canada.

Содержание XS PHONO

Страница 1: ...PASS X Phono s Dual Chassis Phonostage ...

Страница 2: ...r supply cords should be routed so that they are not likely to be walked on abraded or pinched by items placed on or against them paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance insert a cut or damaged power cord into a mains power socket Power and Signal Cables should never be connected disconnected with equipment powered up Failure t...

Страница 3: ...y click into place and lock 1 8 turn to the right c There is no particular preference for which power supply socket feeds either gain chassis socket as long as both are connected 4 Now you can plug the cord into the supply Fig 4 3 and the supply into the AC AC mains 5 it takes upwards of a minute for the system to come up and perform various WAIT housekeeping functions When ready the mute will go ...

Страница 4: ...ption of the low level analog information From the front panel of the X Phono you can select precise resistive loadings from 30 s ohms through 47k ohms capacitive values from 100 pF through 750 pF in addition to gain of 56 dB 66 dB or 76 dB Blue s on the front panel indicate the loading values and LED gain settings For any input choose the loading and gain settings best suited to that cartridge an...

Страница 5: ... recordings When selected the directly LED above the button will show blue The High Pass Filter rolls off the low end response of the X Phono at 6dB per octave The resulting 3dB roll off at 20 Hz maintains much of s the bandwidth you desire while minimizing various low frequency residual artifacts in less than perfect recordings De selecting the Hi Pass function allows more of what is on the recor...

Страница 6: ...apacitive loading 5 Save 3 Gain 6 High Pass Filter 7 Mute X Phono s 160 430 66dB 320 56dB 2 0 0 100 7 5 0 530 76dB 140 1 0 0 75 75 5 0 3 0 4 7 K 1 K 500 3 3 0 250 75 Input 1 Input 2 Input 3 Save Hi Pass Mute 1 2 3 4 5 6 7 Xs Phono Figure 3 1 Power LED 1 ...

Страница 7: ...er CON CON 5 Signal Ground Posts 10 Signal Ground Posts 1 2 3 4 Twist to lock Twist to lock Pass Laboratories 13395 New Airport Rd Suite G Auburn 95602 CA No user serviceable parts inside Pass Laboratories 13395 New Airport Rd Suite G Auburn CA 95602 No user serviceable parts inside Input 1 Input 2 Input 3 Left Channel Input 1 Input 2 Input 3 Right Channel Twist to lock Twist to lock 1 2 3 6 7 8 4...

Страница 8: ...ne is which Insert the power terminated cable end into the matching chassis socket rotate the CON cable end clockwise till the connector locks the cable into place You should be able to hear and feel the connector lock make sure it does To remove a connector pull back on the locking tab rotate the cable end counter clockwise 1 8 turn and remove The X Phono has 3 pairs of inputs and will accept 1 3...

Страница 9: ...etween what works best for the cartridge and what sounds best in your system Start with a dynamic recording the manufacturers suggested resistive loading 100pf and 56 dB gain If the gain seems low increase it to 66 dB if you start hearing distortion of the loudest notes reduce the gain Listening to a wide variety of music try increasing or decreasing the resistive loading As you change the setting...

Страница 10: ...ican product must be returned to the country of origin for warranty service Foreign distributors are only required to offer warranty service on Pass Laboratories product thattheyhaveimported verifiable byserialnumber Please note Conditions of warranty service and customer rights for product purchased outsidetheUnitedStatesmayvarydepending upon thedistributorand local laws Pleasecheck withyourlocal...

Страница 11: ...11 Pass Laboratories 13395 New Airport Rd Suite G Auburn 95602 CA Phone 530 878 5350 Fax 530 878 5358 Web www passlabs com ...

Отзывы: