Do everybody a favor and try not to have shorted output cables.  It 
happens accidentally all the time, and the amplifier is designed to sur-
vive, mostly.

Of  course it’s always possible that something could go wrong.  If  so, 
don’t get excited, just relax.  It’s really aggravating when something like 
this doesn’t work, we understand, but it will get fixed.  We go to a lot 
of  trouble to make products reliable, and the failure rate of  our ampli-
fiers is very low.  This is small comfort to the few, but take it easy and 
give us a call if  you have problems.

People are often interested in how long it takes for these amplifiers 
to break in.  Perhaps a more salient question is how long does it take 
them to reach their sonic best after turn on.  It takes about an hour for 
them to fully warm up, and this is where we adjust them first.  Then 
we adjust them again and again over a couple of  days, keeping the bias 
and offset in the sweet spot.  Our environment is about 23 degrees 
Centigrade and the heat sinks will rise approximately 25 degrees C. 
above that, for an average on heat sink temperature of  48 degrees C.  
Sonically they are at their best when the heatsinks are approximately 
50 degrees C.

In your setup the temperature may vary a bit due to line voltage varia-
tions and ventilation, but this is not a big deal.  You should be able to 
put your hands on the heat sinks without discomfort for 10 seconds 
or so.  It is normal for the heasink temperature to vary side-to-side and 
front to back.

The amplifier has a thermal cutout that will disconnect AC power if  
the temperature exceeds 75 degrees Centigrade.  This should never 
occur in real life.

More things to know

  

You can remotely operate the stand-by mode by applying 12 volts DC 
to the single pair of  binding post connectors on the rear of  the ampli-
fier.  The positive of  the 12 volts DC goes to the red connector.  This 
connection has an actual operating range of  about 9 volts to 15 volts 
at a current draw of  approximately 5.0mA.  This switching will over-
ride the front panel button, so if  you want the front panel button to 
operate, leave the rear connection open.

So much for the most essential information.

You are ready to play music

Содержание X150.5

Страница 1: ...1 X150 5 Owners Manual pass TM X150 5 Owner s Manual May 17 2006 ...

Страница 2: ...tion be tween the two halves of the balanced circuit that further perfects this match Any distortion and noise not already identical to the two halves is made more identical by a factor of about 10 and the result is improved noise cancellation at the output of the amplifier Unlike feedback techniques where the goal is to correct for the distortion by feeding a gain stage an inversely distorted sig...

Страница 3: ...e to explosive transient and back to silence without a trace and without information loss Very unlike conventional high power amplifiers they provide this level of power with a subtlety befitting some of the better tube amplifiers This per formance is consistence across the audio spectrum and the amplifiers are unconditionally stable into all speaker loads So relax and enjoy your amplifier Call us...

Страница 4: ... 2 amp type 3AG 250V slow blow and for units rated at either 100 or 120 volts the fuse will be a 5 amp type 3AG slow blow Do not substitute other types voltage amperage or time constant fuses for the specified replacement The frequency rating of the AC line source in all instances will be 50 to 60 Hz Please verify that the amplifiers indicated voltage requirements are consistent with the line volt...

Страница 5: ...sical size and construction make sure the speaker connections do not short together It is recommended that you connect the speaker ends of these cables first Some powered subwoofers require an audio signal ground reference and their makers may suggest that a black speaker terminal is where this voltage reference might be found On complementary designs which would be typical of all power amps produ...

Страница 6: ...the heat sinks will rise approximately 25 degrees C above that for an average on heat sink temperature of 48 degrees C Sonically they are at their best when the heatsinks are approximately 50 degrees C In your setup the temperature may vary a bit due to line voltage varia tions and ventilation but this is not a big deal You should be able to put your hands on the heat sinks without discomfort for ...

Страница 7: ...ace In these cases take special care that the source does not contain a differential DC component and confirm the differential DC offset of the pre amplifier is sufficiently low This differential voltage is easily adjusted by a qualified technician armed with the appropriate service documents We have a general recommendation about interconnects which is that they should cost less than the amplifie...

Страница 8: ...rience they will last 15 to 20 years before needing replacement Fortunately these components die gracefully typically with years of warning and are easily replaced After that the longevity will depend on the number of operating ther mal cycles but we can attest to having had amplifiers operating in the field in excess of 20 years with no particular mortality except capaci tors We don t have good i...

Страница 9: ...300 uV unweighted 20 20 kHz Balanced CMRR 60 dB 1 kHz input common mode rejection ratio DC offset 100 mv differential Power Consumption 250 watts idle 600 watts maximum Temperature 25 degrees C above ambient at idle Dimensions 19 W x 22 D x 7 5 H Shipping Weight 68 lbs For more information please contact Pass Laboratories Inc P O Box 219 24449 Foresthill Rd Foresthill CA 95631 Tel 530 367 3690 Fax...

Страница 10: ... of origin for warrantee service Foreign distributors are only required to offer warranty service on Pass Laboratories product that they have imported Please note Conditions of warranty service and customer rights for product purchased outside the United States may vary depending upon the distribu tor and local laws Please check with your local distributor for specific rights and details Any modif...

Страница 11: ... that they are not likely to be walked on abraded or pinched by items placed on or against them paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance insert a cut or damaged power cord into a mains power socket Power and Signal Cables should never be connected disconnected with equipment powered up Failure to heed this warning may damage or ...