X150.5 Owners Manual
pass
TM
X150.5 Owner’s Manual
May 17, 2006
Страница 1: ...1 X150 5 Owners Manual pass TM X150 5 Owner s Manual May 17 2006 ...
Страница 2: ...tion be tween the two halves of the balanced circuit that further perfects this match Any distortion and noise not already identical to the two halves is made more identical by a factor of about 10 and the result is improved noise cancellation at the output of the amplifier Unlike feedback techniques where the goal is to correct for the distortion by feeding a gain stage an inversely distorted sig...
Страница 3: ...e to explosive transient and back to silence without a trace and without information loss Very unlike conventional high power amplifiers they provide this level of power with a subtlety befitting some of the better tube amplifiers This per formance is consistence across the audio spectrum and the amplifiers are unconditionally stable into all speaker loads So relax and enjoy your amplifier Call us...
Страница 4: ... 2 amp type 3AG 250V slow blow and for units rated at either 100 or 120 volts the fuse will be a 5 amp type 3AG slow blow Do not substitute other types voltage amperage or time constant fuses for the specified replacement The frequency rating of the AC line source in all instances will be 50 to 60 Hz Please verify that the amplifiers indicated voltage requirements are consistent with the line volt...
Страница 5: ...sical size and construction make sure the speaker connections do not short together It is recommended that you connect the speaker ends of these cables first Some powered subwoofers require an audio signal ground reference and their makers may suggest that a black speaker terminal is where this voltage reference might be found On complementary designs which would be typical of all power amps produ...
Страница 6: ...the heat sinks will rise approximately 25 degrees C above that for an average on heat sink temperature of 48 degrees C Sonically they are at their best when the heatsinks are approximately 50 degrees C In your setup the temperature may vary a bit due to line voltage varia tions and ventilation but this is not a big deal You should be able to put your hands on the heat sinks without discomfort for ...
Страница 7: ...ace In these cases take special care that the source does not contain a differential DC component and confirm the differential DC offset of the pre amplifier is sufficiently low This differential voltage is easily adjusted by a qualified technician armed with the appropriate service documents We have a general recommendation about interconnects which is that they should cost less than the amplifie...
Страница 8: ...rience they will last 15 to 20 years before needing replacement Fortunately these components die gracefully typically with years of warning and are easily replaced After that the longevity will depend on the number of operating ther mal cycles but we can attest to having had amplifiers operating in the field in excess of 20 years with no particular mortality except capaci tors We don t have good i...
Страница 9: ...300 uV unweighted 20 20 kHz Balanced CMRR 60 dB 1 kHz input common mode rejection ratio DC offset 100 mv differential Power Consumption 250 watts idle 600 watts maximum Temperature 25 degrees C above ambient at idle Dimensions 19 W x 22 D x 7 5 H Shipping Weight 68 lbs For more information please contact Pass Laboratories Inc P O Box 219 24449 Foresthill Rd Foresthill CA 95631 Tel 530 367 3690 Fax...
Страница 10: ... of origin for warrantee service Foreign distributors are only required to offer warranty service on Pass Laboratories product that they have imported Please note Conditions of warranty service and customer rights for product purchased outside the United States may vary depending upon the distribu tor and local laws Please check with your local distributor for specific rights and details Any modif...
Страница 11: ... that they are not likely to be walked on abraded or pinched by items placed on or against them paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance insert a cut or damaged power cord into a mains power socket Power and Signal Cables should never be connected disconnected with equipment powered up Failure to heed this warning may damage or ...